The AirTAC AirTAC 4V230E-08AI Solenoid Valve, 5/3-way, exhaust center, PT1/4, AC220V, grommet entry (4V230E08AI) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with 230E08AI ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V230E-08AI is a 5/3-way double-solenoid pneumatic directional valve from the AirTAC 4V200 series, configured with an exhaust center. When both solenoids are de-energized, the spool moves to the middle position where both cylinder ports (A and B) are connected to exhaust, allowing a double-acting cylinder to float freely. This model comes with an AC220V coil and a grommet-style electrical entry with a 0.5 m flying lead, simplifying wiring into a DIN-rail cabinet.
With an effective area of 13.6 mm² (Cv 0.8) and a maximum cycling rate of 3 cycles per second, this 360 g aluminum-body valve suits ~Ø32-50 mm double-acting actuators. The spool shifts in 0.05 s or less, and the IP65-rated enclosure protects the 4.5 VA AC coil in dusty or washdown environments.
| Model | AirTAC 4V230E-08AI Solenoid Valve, 5/3-way, exhaust center, PT1/4, AC220V, grommet entry (4V230E08AI) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | 230E08AI |
| Exhaust port | 230E08AI |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -230E08AI | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
Operators can manually move a double-acting cylinder by hand when the valve is de-energized, as the exhaust center dumps all air pressure. Ideal for conveyor diverters that need frequent manual adjustment during product changeovers.
In assembly cells, a 5/3 exhaust-center valve ensures that a clamping cylinder immediately releases its grip upon an E-stop, allowing the part to be removed without trapped residual pressure.
Used to control a press platen that must float freely during the return stroke or when the machine is idle, preventing any unintended force build-up on tooling or parts.
Choose the 4V230E-08AI when your application needs a cylinder to go limp at mid-stroke—common for manual positioning or emergency-release setups where residual pressure must be dumped. The 5/3 exhaust center is the correct choice over a closed center (30C) when you do not want the cylinder to hold position at rest. If your cylinder bore is below Ø25 mm and speed is less critical, the smaller 4V100 body (Cv 0.6) may be a better fit; for bores above Ø63 mm or faster cycling, step up to the 4V300 series (Cv 1.65).
When replacing an existing valve, match five points: the 4V200 body size, the 5/3 exhaust-center function (30E), the 1/4-inch PT port, the AC220V coil voltage, and the grommet (flying-lead) electrical entry. This valve can be used individually or on a manifold base for multi-station pneumatic panels.
Quick checklist
In the center (de-energized) position, both the A and B cylinder ports are connected to the exhaust ports. This means no compressed air is trapped in the cylinder, allowing a double-acting cylinder rod to be moved freely by an external force. It is the opposite of a closed center, which blocks all ports to hold the cylinder in place.
No. The 4V230E-08AI has a 4.5 VA AC220V coil specifically wound for alternating current. Applying DC voltage will not operate the valve correctly and will burn out the coil. For a DC24V version with the same grommet entry, you would need the 4V230E-08BI model.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.