The AirTAC AirTAC 4V230E-08E Solenoid Valve, 5/3-way, exhaust center, PT1/4, AC24V, terminal entry (4V230E08E) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with 230E08E ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V230E-08E is a 5/3-way double-solenoid pneumatic directional valve with an exhaust center, built on the compact 4V200 aluminum body. When both solenoids are de-energised, the spool shifts to its center position where cylinder ports A and B are connected to exhaust while the inlet is blocked. This allows a double-acting cylinder to float freely, making it ideal for applications where the load needs to be manually repositioned or where pressure must not be trapped during an emergency stop.
With 1/4in PT inlet and outlet ports and a 1/8in PT exhaust, this valve delivers an effective area of 13.6 mm2 (Cv 0.8), suiting pneumatic cylinders in the ~O32-50 mm range. The AC24V coil draws5.0 VA and the spool responds in0.05 seconds or less. The IP65-rated terminal box keeps wiring tidy, and the locking manual override simplifies commissioning.
| Model | AirTAC 4V230E-08E Solenoid Valve, 5/3-way, exhaust center, PT1/4, AC24V, terminal entry (4V230E08E) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | 230E08E |
| Exhaust port | 230E08E |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -230E08E | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
The exhaust center lets an operator manually push or pull a pneumatic axis into position during setup or after an E-stop, since both sides of the cylinder vent to atmosphere.
When a safety circuit drops power to both solenoids, the cylinder immediately exhausts, removing stored energy so a guard door or clamp cannot exert force.
A gate or diverter driven by a double-acting cylinder can be designed to fall to a safe position under gravity when the valve centers and exhausts both ports.
Choose the 4V230E-08E when your application needs a double-acting cylinder to go limp at mid-stroke rather than holding position. This is common on manual load-assist stations, doors that must be pushable when power is off, or any axis where trapped air would create a hazard. If you instead need the cylinder to lock in place when the valves are centered, select the closed-center 4V230C-08 variant.
For smaller cylinders around O20-32 mm, the 4V100 series (Cv 0.6) reduces oversizing and saves manifold space. For larger bores above O50 mm or faster cycle rates, step up to the 4V300 body (Cv 1.65). When replacing an existing valve, match all five points: 4V200 body size, 5/3 exhaust-center function, 1/4in PT thread, AC24V coil voltage, and terminal-box electrical entry.
Quick checklist
In the center position (both solenoids off), the inlet port is closed and both cylinder ports A and B are connected to exhaust. The cylinder is not pressurised on either side, so the piston rod can be moved freely by an external force.
No. The 4V230E-08E has a5.0 VA AC24V coil designed for alternating current only. Connecting it to DC24V will burn out the coil. For a DC24V supply, order the 4V230E-08B variant, which uses a3.0 W DC coil.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.