verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 4V Series · 5/3-way Solenoid Valve

AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08B-W)

The AirTAC AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08B-W) is a genuine 5/3-way 5/3 double solenoid — pressure center solenoid valve with W ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Pressure center
  • Port sizeW
  • Effective area13.6 mm²
  • Flow (Cv)0.8
  • Series4V200
$53.63 $58.64Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V230P-08 stroke, mounting and version on one page All 4V230P-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08B-W)

The 4V230P08B-W is the 4V200 body built as a 5/3 pressure-center valve: two solenoids shift the spool, and when both are de-energised it holds both cylinder ports A and B under pressure while supply and exhaust stay blocked. That center condition keeps a double-acting cylinder pre-loaded on both sides, which is useful where you want balanced pressure on the actuator between strokes. At center the valve still flows through its 5/3 class effective area of 13.6 mm2 (Cv 0.8), and it switches in 0.05 s or less.

The -W suffix marks the external-pilot version: pilot air enters through a dedicated external pilot port rather than being tapped from the main line inside the valve, so shifting stays dependable when the main supply runs at low pressure or in vacuum circuits. This exact SKU is wired for DC24V with a 3.0 W coil on terminal-box connections and PT (Rc tapered) 1/4 ports, weighs 360 g, and pairs naturally with O32-50 mm double-acting cylinders.

AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08B-W) Technical Specifications

ModelAirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08B-W)
Series4V200 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Pressure center
Port sizeW
Exhaust portW
Effective area (Cv)13.6 mm² (Cv 0.8)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight360 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area13.6 mm²
Flow coefficientCv 0.8
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08B-W)

4VSolenoid valve, spool type, 4-series.
2Body size (4V200) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-WPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08B-W) Is Used

precision_manufacturing

Balanced clamping between cycles

Pressure center keeps both sides of a double-acting clamp cylinder pressurised while the valve sits idle, so the actuator stays evenly loaded between press and release strokes.

science

Vacuum and low-pressure circuits

The external-pilot -W construction shifts reliably where the main line cannot feed the pilot internally, making it a fit for vacuum handling and low-pressure process stations.

factory

Packaging and assembly actuators

Drives O32-50 mm double-acting pushers and lifters on packaging and assembly lines, with a DC24V 3.0 W coil that suits standard 24 V control panels and PLC outputs.

Is the AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08B-W) the Right Valve?

Pick this valve when the center state you need is both cylinder sides pressurised, and when your main-line pressure is too low or too unstable to drive an internal pilot - the -W external pilot takes its signal from a separate port instead. If you would rather have the cylinder held in position, choose the closed-center 30C; if the cylinder should float freely, the exhaust-center 30E is the right center. For a small bore running slowly, step down to the 4V100 (Cv 0.6); for larger bores or faster cycling, the 4V300 (Cv 1.65) gives more headroom. Bases let you gang several 4V200 valves into one manifold block.

When replacing, match five points exactly: 4V200 body, 5/3 pressure-center function (30P), port plus thread (1/4 PT here), coil voltage (DC24V, 3.0 W), and electrical entry (terminal box) - plus the external-pilot -W option if your piping relies on it.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08B-W) FAQ

It controls double-acting cylinders and actuators in the O32-50 mm range, flowing 13.6 mm2 (Cv 0.8) with switching in 0.05 s or less. Because it is a pressure-center (30P) valve, de-energising both solenoids pressurises cylinder ports A and B at the same time while blocking supply and exhaust - the two sides of the cylinder stay under balanced pressure. It is not a safety brake: for suspended or hazardous loads, add a pilot-operated check valve or a mechanical brake at the cylinder.

The -W option feeds pilot air through an external port instead of drawing it from the main supply inside the valve, so the spool still shifts cleanly on low-pressure or vacuum mains where an internally piloted valve could stall. The DC24V coil draws only 3.0 W, connects through a terminal box, and matches standard 24 V control circuits; ports are 1/4 PT (Rc tapered) on the 4V200 body.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08B-W)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V230P08B-W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.