The AirTAC AirTAC 4V330C-10BI Solenoid Valve, 5/3-way, closed center, PT3/8, DC24V, grommet entry (4V330C10BI) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with 330C10BI ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330C-10BI is a 5/3-way double-solenoid pneumatic directional valve that precisely controls double-acting cylinders and actuators. In its de-energized center position, all ports are blocked—this closed-center configuration holds the cylinder firmly in place, making it the go-to choice for applications where drift during a mid-stroke stop is unacceptable. With a 21.3 mm² effective area (Cv 1.25), it suits ~Ø50-80 mm cylinders, and the DC24V coil draws just 3.0 W.
This particular model arrives with a grommet-style electrical entry—a 0.5 m pre-wired flying lead that simplifies DIN-rail wiring and keeps the IP65 protection intact. The spool shifts in 0.05 s or less, and the aluminum-alloy body weighs 450 g. It operates on filtered, non-lubricated air from 0.15-0.8 MPa and can be banked on a manifold base for multi-cylinder systems.
| Model | AirTAC 4V330C-10BI Solenoid Valve, 5/3-way, closed center, PT3/8, DC24V, grommet entry (4V330C10BI) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | 330C10BI |
| Exhaust port | 330C10BI |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -330C10BI | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Holds pneumatic clamps at a precise mid-stroke position during machining or welding, preventing part movement when the valve center is closed.
Commands a lift or stop gate to pause mid-travel on a conveyor line, keeping the actuator locked until the next pulse resumes the cycle.
Allows a press cylinder to dwell under position control—the closed center blocks both cylinder ports so the ram doesn't creep during a heating or curing phase.
Choose the 4V330C-10BI when your double-acting cylinder must lock position at mid-stroke without air consumption holding it—the closed center is purpose-built for that. If your cylinder is smaller (Ø32-40 mm), the 4V200 series (Cv 1.0) may be a better match; for larger bores above 80 mm, step up to the 4V400 (Cv 2.82). This is a double-solenoid valve, so it needs only a momentary pulse to shift and will stay in its last commanded position even if power is lost.
For a drop-in replacement, match five points: body size (4V300), function (5/3 closed-center, code 30C), port and thread (3/8" PT), coil voltage (DC24V), and electrical entry (grommet with flying lead). The grommet entry is especially useful in cabinets where a terminal box would be awkward to reach.
Quick checklist
In the center (de-energized) position, all five ports are blocked. The cylinder ports A and B are sealed, so the piston is held in place by trapped air. This is ideal for mid-stroke stops where you cannot allow the load to drift. Note that for true load-holding safety, a pilot-operated check valve at the cylinder is still recommended.
This specific SKU (4V330C-10BI) is built with a DC24V coil (3.0 W). If your system runs on AC220V or AC110V, you would need the corresponding voltage code—for example, 4V330C-10AI for AC220V with a grommet entry. Always match the coil voltage exactly to avoid burnout or slow shifting.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.