The AirTAC AirTAC 4V420-15 Solenoid Valve, 4V400 Series (4V42015C-AM) is a genuine 5/2-way double solenoid (memory) solenoid valve with AM ports and an effective area of 48.0 mm² (Cv 2.82). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V42015C-AM is the double-solenoid 5/2 valve in AirTAC's largest 4V body, built to switch compressed air between the two sides of double-acting cylinders and actuators through 1/2-inch PT ports. As a memory valve it keeps whichever position it was last pulsed into: land friction and balanced pressure hold the spool, so no spring pulls it back and no current is needed to keep it there - it is not magnetically latched. An effective area of 48 mm2 (Cv 2.82) puts it in the flow class that suits bores of roughly 80-125 mm.
This specific SKU pairs AC110V mains operation and a terminal-box electrical entry with the factory -AM option: an AMISCO (Italian) solenoid coil replaces the standard AirTAC coil. The valve's ports, function and flow are unchanged, but the AMISCO coil's VA rating is not covered by our published data, so confirm that figure with us when ordering. The valve itself weighs 720 g, reacts in 0.05 s or less and cycles up to 3 times per second.
| Model | AirTAC 4V420-15 Solenoid Valve, 4V400 Series (4V42015C-AM) |
|---|---|
| Series | 4V400 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | AM |
| Exhaust port | AM |
| Effective area (Cv) | 48.0 mm² (Cv 2.82) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 720 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 48.0 mm² |
|---|---|
| Flow coefficient | Cv 2.82 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 4 | Body size (4V400) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -AM | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V410 (single), 4V420 (double), 4V430C/E/P (5/3 center). Add the voltage suffix when ordering.
A brief pulse extends or retracts a large 80-125 mm clamp cylinder and the valve simply keeps that state until the next pulse, so the control circuit never has to hold a coil energised through the whole clamping cycle.
Double-acting cylinders in the 80-125 mm class on forming, pressing and indexing stations get the full 48 mm2 (Cv 2.82) flow path, switching direction at up to 3 cycles per second from a 110 V AC control supply.
Bulk-flow slide gates, flap diverters and heavy gate actuators need force and a position that persists between commands - the memory spool delivers both without drawing holding power at the terminal box.
Step up to this 4V400 body once a 4V300 (Cv 1.65) can no longer keep your cylinder cycle time on target; for flow above Cv 2.82 you would move to a larger valve series or gang several valves on a manifold base. Inside the 4V400 range, take the single-solenoid 4V410 when a spring-return signal is wanted, this 420 when pulsed memory switching suits your circuit, and a 430C/E/P variant when a true 5/3 center action is needed. For a like-for-like replacement check five points: body size (4V400), function (20), port and thread (1/2-inch PT), coil voltage (AC110V), electrical entry (terminal) - and whether your original carried the -AM AMISCO coil.
Quick checklist
It is a 5/2 valve intended for double-acting cylinders only. Its 48 mm2 effective area (Cv 2.82) at 1/2-inch PT ports comfortably serves bores in the ~80-125 mm range, switching at up to 3 cycles per second. Smaller bores can be handled more economically by a 4V300 (Cv 1.65).
Because this SKU includes the -AM option: the standard coil is replaced at the factory by an AMISCO (Italian) coil, and its VA rating does not appear in our published 4V400 data. The valve still operates on AC110V via the terminal box, and we will confirm the exact AMISCO rating with you before dispatch.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.