The AirTAC AirTAC 4V420-15 Solenoid Valve, 4V400 Series (4V42015H-AM) is a genuine 5/2-way double solenoid (memory) solenoid valve with AM ports and an effective area of 48.0 mm² (Cv 2.82). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
4V420-15H-AM is the 1/2in PT version of AirTAC's 4V400 double-solenoid body - a 5/2 spool valve that sends compressed air to one side of a double-acting cylinder while exhausting the other. As a function 20 valve, a short pulse on either solenoid latches the spool in that position; the hold comes from balanced pressure and land friction, not from a magnet or a spring, and no current is needed to keep a slide or gate where you left it. Flow is the widest in the 4V range: 48.0 mm2 effective area, Cv 2.82, switching in 0.05 s or less.
The H-coded coil in this SKU is a non-standard voltage variant - confirm your control supply (AC or DC, and the voltage) before ordering so the correct coil ships. The screw-terminal box is IP65 to DIN40050, the aluminium body weighs 720 g, it tolerates 0.15-0.8 MPa and -20 to +70 C, needs no lubrication, and stacks into an integrated manifold group on a common base.
| Model | AirTAC 4V420-15 Solenoid Valve, 4V400 Series (4V42015H-AM) |
|---|---|
| Series | 4V400 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | AM |
| Exhaust port | AM |
| Effective area (Cv) | 48.0 mm² (Cv 2.82) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 720 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 48.0 mm² |
|---|---|
| Flow coefficient | Cv 2.82 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 4 | Body size (4V400) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -AM | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V410 (single), 4V420 (double), 4V430C/E/P (5/3 center). Add the voltage suffix when ordering.
Drives a O125 mm ejector cylinder - roughly 614 kgf of push at 0.5 MPa - on single-pulse commands from the press controller, with the spool latching and no holding current.
Cycles a O100 mm log stop (~390 kgf at 0.5 MPa) beside a chain conveyor; if a signal drops mid-shift the stop stays where it was last pulsed, with pilot-operated checks at the ports backing it up on inclines.
Swings a heavy booth access door on a O80 mm cylinder (~250 kgf at 0.5 MPa); the non-lubricated circuit with 40 um filtration copes well with dusty coating-shop air.
If your actuator is smaller than the ~O80-125 mm window this body suits - say an O63 bore pushing about 156 kgf at 0.5 MPa - the 4V300 with Cv 1.65 will do the job at lower cost. There is no larger 4V body: for an O150 bore (about 880 kgf push at 0.5 MPa) or higher flow demand, move to a bigger AirTAC valve series or build a manifold group on a base. Use this double-solenoid code where two-wire pulse commands are wanted and the actuator must stay put between pulses; select function 10 for spring-return duty or 30C/E/P for a 5/3 center. For a like-for-like swap verify: 4V400 body, function 20, 1/2in port with PT thread, coil code H with its voltage confirmed, and terminal-box entry.
Quick checklist
Key set: 5/2 double-solenoid function, 48.0 mm2 effective area (Cv 2.82), max 3 cycles per second, response 0.05 s or less, 0.15-0.8 MPa operating pressure against a 1.2 MPa proof, 720 g aluminium body, IP65 terminal box, 1/2in PT ports. Match all of these plus the H coil code - confirming its voltage with us first - for a drop-in swap.
The spool stays in its last pulsed position by balanced pressure and land friction - there is no spring and no holding current - which is dependable for horizontal slides and gates. For suspended loads never rely on the valve alone: fit pilot-operated check valves at the cylinder ports or a dedicated mechanical brake, and let this valve act as the directional control in front of them.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.