The AirTAC Airtac GAC F.R.L. Unit GAC200C06ALWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for compact pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 1/8in port, a 5 um element and a lower pressure range of 0.15-0.4 MPa (20-58 psi). The metal bowl provides a robust housing for the 25 cc condensate sump and 36 cc oil reservoir.
Air passes through the filter first, then the regulator, before oil mist is introduced downstream by the lubricator so the regulator seat stays clean. An automatic drain clears condensate without operator intervention, and a circular gauge reading MPa/psi is fitted for the default PT thread. This assembly also includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol with details on its own page.
| Model | Airtac GAC F.R.L. Unit GAC200C06ALWK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure actuated clamping pins in electronics assembly where delicate handling requires a strict 0.4 MPa ceiling.
Conditions air for precision fluid dispensing valves, using the 5 um element to protect sensitive nozzles from particulate fouling.
Supplies a steady oil mist to miniature air grinders in a repair bench, relying on the automatic drain to clear moisture continuously.
Choose this 750 g assembly for single actuators or small jigs where the machine needs a maximum of 0.4 MPa. The 5 um element traps far finer particles than the standard 40 um grade, suiting precision valves, though it requires more frequent element service. If the line must stay oil-free, omit the lubricator and choose a filter-regulator instead. The three units are separately orderable as GAF200-06, GAR200-06 and GAL200-06, so a damaged bowl does not mean replacing the whole assembly. The catalogue flow curve for the GAC200 is plotted to 1750 L/min at 0.7 MPa inlet, which is about 29% of the GAC300's 3000 L/min envelope. Because the lower-pressure type tops out at 0.4 MPa, it reaches only 44% of the standard 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure model regulates from 0.15-0.4 MPa (20-58 psi). It has a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 25 cc and the oil bowl holds 36 cc, with a total weight of 750 g. The recommended lubricant is ISO VG 32.
The K indicates that a reverse-flow (reflux) valve is fitted to this unit. The catalogue displays this as a distinct pneumatic symbol with specific details provided on its own page.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.