verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAC200 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC200N06ALNWK

The AirTAC Airtac GAC F.R.L. Unit GAC200N06ALNWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight750 g
$88.53 $98.19Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC200N06ALNWK

Delivering cleaned, regulated and lubricated air for a single actuator, this AirTAC GAC200N06ALNWK F.R.L. combination integrates a filter, regulator and lubricator on one L-shape bracket. The 1/8in port and 750 g weight place it in the smallest size class, while the 5 um element traps fine particles for precision pneumatic work. Air flows through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls.

This specific unit features a nylon bowl and an automatic drain, clearing condensate from the 25 cc bowl without an operator present. The lower pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi). Because the code includes an N after the port, no gauge is supplied; the 1/8in gauge connection allows adding one later to read the set pressure. A reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page.

Airtac GAC F.R.L. Unit GAC200N06ALNWK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC200N06ALNWK
SeriesGAC200 F.R.L. combination
Port size1/8" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC200N06ALNWK

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
06Port size 1/8". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/8" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC200N06ALNWK Is Used

precision_manufacturing

Micro-Assembly Jigs

Feeds single-actuator pick-and-place probes requiring 5 um filtered, low-pressure air for delicate electronics handling.

science

Laboratory Pneumatics

Conditions air for sensitive analytical instruments operating within the 0.15-0.4 MPa range, with the automatic drain handling condensate unattended.

handyman

Small Air Tools

Supplies a controlled oil mist to miniature air grinders or screwdrivers in a benchtop repair station via the 1/8in port.

Is the Airtac GAC F.R.L. Unit GAC200N06ALNWK the Right Air-Prep Unit?

Choose this 1/8in unit for compact jigs requiring precise, low-pressure air with fine filtration. The 5 um element suits instrument air or sensitive valves, though it requires more frequent service than the standard 40 um grade. If your machine might ever exceed 0.4 MPa, this lower-pressure type is the wrong part, as the standard type regulates up to 0.9 MPa. The automatic drain is decisive for unattended or wet lines, and the nylon bowl should be confirmed for compatibility in aggressive chemical surroundings. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead. The three units are separately orderable as GAF200-06, GAR200-06 and GAL200-06, so a clogged element does not require replacing the whole assembly. Stepping up to the GAC300 body increases the condensate bowl from 25 cc to 60 cc, an 2.4x capacity gain that reduces intervention frequency.

Quick checklist

  • ✓ Body size for your peak flow (1/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC200N06ALNWK FAQ

This model operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 25 cc drain bowl, a 36 cc oil bowl, and weighs 750 g. The recommended lubricant is ISO VG 32 or equivalent.

The N in the code signifies no gauge is supplied; you can add one to the 1/8in gauge connection to read the set pressure. The K indicates a reverse-flow (reflux) valve is fitted, which the catalogue draws as a separate pneumatic symbol with details on its own page.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC200N06ALNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC200N06ALNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.