The AirTAC Airtac GAC F.R.L. Unit GAC200N06LNWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for compact pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/8in port and 750 g weight make it ideal for feeding a single small actuator or jig. Because the 5 um element sits upstream of the pressure setting, the regulator seat stays clear of debris while the lubricator introduces oil mist downstream.
Configured for low-pressure duties, the regulator operates from 0.15-0.4 MPa (20-58 psi). The nylon bowl holds 25 cc of condensate and 36 cc of oil. A reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol on its own page. No gauge is supplied, but a 1/8in connection is available if you need to add one to monitor the set pressure.
| Model | Airtac GAC F.R.L. Unit GAC200N06LNWK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate pick-and-place actuators where a 1/8in port and 5 um filtration protect tiny precision valves from grit.
Suitable for benchtop test rigs requiring a stable 0.15-0.4 MPa output and a compact 750 g footprint.
Provides regulated, lubricated air to low-pressure miniature grinders or screwdrivers, extending tool life via downstream oil mist.
Choose this assembly for low-pressure circuits requiring fine 5 um filtration, matching the PT thread and MPa/psi gauge scale to your existing fittings. The semi-auto and manual drain pair handles condensate for attended machines. If your downstream line must remain oil-free, omit the lubricator and select a separate filter-regulator instead. Should the element clog or a bowl crack, order the GAF200-06, GAR200-06 and GAL200-06 spares individually rather than replacing the whole assembly.
Stepping up to the GAC300 body raises the plotted flow envelope from 1750 to 3000 L/min at 0.7 MPa inlet, whereas this compact 750 g unit is built for minimal flow duties. The 0.4 MPa upper limit is 44% of the standard 0.9 MPa ceiling, so verify your machine will never need higher pressure before specifying this L type.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 750 g, and features a 25 cc drain bowl alongside a 36 cc oil bowl. The recommended lubricant is ISO VG 32 or equivalent.
The N in the code means no gauge is supplied, but you can fit one using the 1/8in gauge connection. The K indicates a reverse-flow (reflux) valve is fitted, which the catalogue draws as a separate pneumatic symbol with details on its own page.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.