The AirTAC Airtac GAC F.R.L. Unit GAC400C15ALW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatics, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in ported body carries a 5 um element to trap fine particles before they reach precision valves, operating within the lower 0.15-0.4 MPa (20-58 psi) pressure band.
Air passes through the filter first, then the regulator, with oil mist added last so the regulator seat stays clean. The metal bowl equips this 2390 g assembly for rugged environments, while the automatic drain clears condensate from the 100 cc bowl without an operator. A circular gauge reading MPa/psi is fitted for the default PT thread, letting technicians verify the set pressure directly.
| Model | Airtac GAC F.R.L. Unit GAC400C15ALW |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds instrument air to sensitive solenoid valve banks, leveraging the 5 um element to prevent sticking and ensure accurate shifting in packaging machinery.
Regulates down to the 0.15-0.4 MPa range for delicate pneumatic presses that assemble electronics, preventing damage to fragile components.
Supplies steady, lubricated air to high-speed carton sealing actuators, with the automatic drain handling condensate during continuous daily runs.
Choose this model for 1/2in lines requiring a low 0.15-0.4 MPa (20-58 psi) operating range and fine 5 um filtration. The metal bowl suits harsher industrial settings compared to standard PC or nylon options. Because the automatic drain handles condensate evacuation independently, it is well suited for unattended stations. If the downstream line must remain completely oil-free, omit the lubricator and choose a filter-regulator instead. The three constituent units are separately orderable as GAF400-15, GAR400-15 and GAL400-15, meaning a clogged element does not require replacing the whole assembly. Stepping up to this body gives a flow envelope plotted to 6000 L/min at 0.7 MPa inlet, which is double the 3000 L/min envelope of the GAC300. Keep in mind that 0.4 MPa is 44% of the 0.9 MPa ceiling found on standard type units, so verify your machinery never requires higher pressure.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 1/2in port, a 5 um element, and a temperature range of -5 to 70 C. The drain bowl holds 100 cc, the oil bowl holds 185 cc, the recommended lubricant is ISO VG 32, and the unit weighs 2390 g.
The 5 um element (denoted by the W code) traps far finer particles than the standard 40 um filter, making it ideal for protecting precision valves and instrument air systems, though it requires more frequent element service. The metal bowl (C code) is selected for rugged environments where chemical or impact resistance might be a concern, sharing the exact same 1.0 MPa max pressure rating as the PC and nylon alternatives.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.