The AirTAC Airtac GAC F.R.L. Unit GAC400N15AL is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/2in port serves mid-range machinery, and the 40 um element captures solid particulates before they reach downstream valves. Air flows through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls.
Configured for low-pressure duties, the regulator operates within a 0.15-0.4 MPa (20-58 psi) range. The nylon bowl houses an automatic drain that expels condensate without an operator, holding up to 100 cc of water, while the 185 cc oil reservoir sets the lubrication interval. A circular gauge is fitted, reading MPa/psi for the default PT thread, allowing operators to monitor the set pressure directly.
| Model | Airtac GAC F.R.L. Unit GAC400N15AL |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate pneumatic grippers and sealing jaws on flow-wrapping lines where actuator forces must stay below 0.4 MPa to prevent crushing product.
Conditions air for looms and spinning frames that rely on gentle, consistent cylinder pressure to handle fragile yarns without snags.
Supplies metered, lubricated air to low-force analytical instruments and sample-handling robots requiring stable, sub-0.4 MPa operation.
Choose this 2390 g assembly for machines requiring a stable, lower outlet ceiling of 0.4 MPa; if the equipment might ever demand higher force, the L type is the wrong part. The nylon bowl suits standard plant environments, and the automatic drain is decisive for unattended or wet lines. Because the lubricator introduces oil mist downstream, select a separate filter-regulator if the application requires strictly dry, oil-free air. Should the element clog or a bowl crack, the three units are separately orderable as GAF400-15, GAR400-15 and GAL400-15. Stepping down to the GAC300 reduces the plotted flow envelope from 6000 L/min to 3000 L/min at 0.7 MPa inlet, whereas moving up to the GAC500 keeps a similar flow but changes the port. The 0.4 MPa upper limit is 44% of the Standard type's 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type regulates from 0.15-0.4 MPa (20-58 psi) against a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 2390 g, and pairs a 100 cc drain bowl with a 185 cc oil bowl using ISO VG 32 lubricant.
The A in the ordering code specifies an automatic drain that clears condensate from the 100 cc nylon bowl without manual intervention, making it ideal for unattended stations. The fitted circular gauge reads in MPa/psi to match the default PT thread.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.