verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300C15SNWK

The AirTAC Airtac GAFC Air Service Unit GAFC300C15SNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1020 g
$80.92 $90.07Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300C15SNWK

This AirTAC GAFC300C15SNWK is a two-piece F.R.L. combination. The first body houses both the filter and the regulator, so air is cleaned and set to pressure before it moves on. The second body is the lubricator, which adds a metered oil mist downstream. With a 1/2in port and a 1020 g mass, it suits medium-size machine headers where a single point of air preparation is needed.

The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a 5 um element for finer filtration. The metal bowl is specified by the C code. No gauge is supplied on this model, so the gauge connection (1/8in) is where one would be added. The reverse-flow (reflux) valve is fitted, and the catalogue shows it as a separate pneumatic symbol.

Airtac GAFC Air Service Unit GAFC300C15SNWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300C15SNWK
SeriesGAFC300 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC300C15SNWK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/2" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300C15SNWK Is Used

precision_manufacturing

Precision valve control

Feed a bank of pneumatic valves on a small assembly station. The 5 um element protects fine internal passages from particle wear, while the regulator holds the set pressure for consistent actuator force.

factory

Machine tool lubrication

Supply a single-axis drilling or tapping unit with filtered, regulated air and a controlled oil mist. The 60 cc condensate bowl and 98 cc oil bowl support a full shift between checks.

build

Packaging line retrofit

Upgrade a carton-erecting machine's air prep. The 1/2in port and 1020 g weight fit existing headers, and the metal bowl suits a plant floor where accidental impacts are possible.

Is the Airtac GAFC Air Service Unit GAFC300C15SNWK the Right Air-Prep Unit?

Choose the GAFC300 body for flows up to the plotted 3500 L/min envelope at 0.7 MPa inlet, a step up from the GAFC200's 1750 L/min curve. The 1/2in port (code 15) is the largest offered on this body. The metal bowl is a build choice; the shared specification of 1.0 MPa max and -5 to 70 C applies regardless, so confirm it suits your environment. The semi-auto drain dumps condensate on pressure drop, with a manual backup. The 5 um element traps finer particles than the standard 40 um, at the cost of more frequent service. The PT thread carries a MPa/psi gauge scale, but no gauge is fitted here. The K code adds the reverse-flow valve. Spares are the GAFR300-15 filter & regulator and the GAL300-15 lubricator. With a 1.0 MPa max supply, there is about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan inlet pressure near maximum if you need the full output.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300C15SNWK FAQ

This F.R.L. combination operates at 0.15-0.9 MPa (20-130 psi) with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. The temperature range is -5 to 70 C. It has a 60 cc drain bowl and a 98 cc oil bowl, weighs 1020 g, and uses ISO VG 32 lubricant. The 5 um element and metal bowl are fitted.

The N after the port code means no gauge is supplied. The GAFC300 body has a 1/8in gauge connection, so a circular gauge with an MPa/psi scale (matching the PT thread) can be added there. Without one, the set pressure cannot be read directly on the unit.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300C15SNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300C15SNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.