verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GF200 · Air Filter (water separation + particulate filtration)

AirTAC GF200-06 Filter (GF20006M)

The AirTAC AirTAC GF200-06 Filter (GF20006M) is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 40 µm element, with PT1/8" ports and a manual drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizePT1/8"
  • Filtering grade40 µm
  • DrainManual drain
  • Inlet pressure0 - 0.9 MPa (0 - 131 psi)
  • Bowl materialPC
  • ThreadPT
  • BracketMounting bracket included
$21.85 $26.07Save 16% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GF200 stroke, mounting and version on one page All GF200 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GF200-06 Filter (GF20006M)

The GF series is an air filter only: it removes water and particulate from compressed air, with no regulation and no lubrication. This GF20006M is built at size 200 with 1/8 in. PT ports, carries the standard 40 um element, and the M suffix specifies a manual drain, so accumulated condensate is released by hand as part of routine checks. A mounting bracket is included. With a manual drain the maximum inlet pressure is 0.9 MPa (130 psi), the temperature range is -5 to 70 C (non-freezing), and the size 200 bowl is polycarbonate (PC).

This is a genuine AirTAC part. The GF range covers sizes 200, 300, 400 and 600 with ports from 1/8 in. to 1 in., with a choice of drain type (differential-pressure, automatic or manual), 40 um or 5 um filtration, bracket option, and PT, G (BSPP) or NPT threads; at size 600 the bowl is aluminium alloy. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.

AirTAC GF200-06 Filter (GF20006M) Technical Specifications

ModelAirTAC GF200-06 Filter (GF20006M)
SeriesGF200 air filter
Port sizePT1/8" (PT thread)
Filtering grade40 µm
Drain typeManual drain
BracketMounting bracket included
FluidCompressed air
Inlet pressure0 - 0.9 MPa (0 - 131 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GF200-06 Filter (GF20006M)

GF200G-series air filter, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain. Options are differential (blank), automatic (A) or manual (M).
(blank)Mounting bracket included. A bracket ships by default; J orders it without.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF200 · PT1/8" · 40 µm
One size upGF300
Line orderFilter first, then regulator, then lubricator

Where the AirTAC GF200-06 Filter (GF20006M) Is Used

handyman

Garage air-tool drop filter

A manual-drain filter on a small workshop drop, where the operator bleeds accumulated water during daily compressor checks.

build

Compressor drop-leg water removal

Fitted in a drop leg off a shop air main to collect condensate and particulate, with manual draining built into routine maintenance rounds.

local_shipping

Vehicle service bay air supply

Conditioning shop air for impact wrenches and inflation stations in a truck or car service bay, with the drain checked as part of the shift routine.

Is the AirTAC GF200-06 Filter (GF20006M) the Right Filter?

Size 200 with 1/8 in. PT ports is the smallest step of the G series, matched to light point-of-use duties; step up to 300, 400 or 600 for larger ports and higher flow. The M code specifies a manual drain, which sets the maximum inlet pressure at 0.9 MPa (130 psi) and puts draining on a routine-check schedule; the differential-pressure default and the automatic (A) drain are the alternatives, rated to 1.0 MPa (145 psi). The element is the standard 40 um (W gives 5 um) and a bracket is included. Thread is PT as standard, with G (BSPP) and NPT to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0 - 0.9 MPa (0 - 131 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 40 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

AirTAC GF200-06 Filter (GF20006M) FAQ

Flow for the GF series is published as curves, not as a single rated figure, so we do not state a number on this page. Tell us your line pressure and demand and we will confirm the datasheet curve and correct size for the application on request.

M specifies a manual drain: condensate is released by hand during routine checks instead of by the differential-pressure or automatic drain. With a manual drain the maximum inlet pressure is 0.9 MPa (130 psi) rather than 1.0 MPa. The 40 um element, 1/8 in. PT ports and included bracket are unchanged.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GF200-06 Filter (GF20006M)

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GF20006M and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.