verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GF400 · Air Filter (water separation + particulate filtration)

AirTAC GF400-10 Filter (GF40010MJW)

The AirTAC AirTAC GF400-10 Filter (GF40010MJW) is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 5 µm element, with PT3/8" ports and a manual drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizePT3/8"
  • Filtering grade5 µm
  • DrainManual drain
  • Inlet pressure0 - 0.9 MPa (0 - 131 psi)
  • Bowl materialPC
  • ThreadPT
  • BracketSupplied without bracket
$37.73 $42.36Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GF400 stroke, mounting and version on one page All GF400 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GF400-10 Filter (GF40010MJW)

The AirTAC GF40010MJW is a GF-series air filter in the 400 size with a 3/8" PT port. Filtration only: it removes water and particulate from compressed air - no regulation, no lubrication. The W suffix specifies the finer 5 um filter element instead of the standard 40 um, for lines where precision valves, cylinders or instruments need cleaner air. Drainage is manual, no mounting bracket is supplied (J), and the 400-size bowl is polycarbonate.

This is a genuine AirTAC part. The GF family runs sizes 200/300/400/600 with ports 1/8" to 1", and offers G (BSPP) or NPT threads, automatic or manual drains, and bracket options. Flow for the series is published as curves rather than a single rated figure, so contact us and we will confirm the datasheet figures for your application on request.

AirTAC GF400-10 Filter (GF40010MJW) Technical Specifications

ModelAirTAC GF400-10 Filter (GF40010MJW)
SeriesGF400 air filter
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Drain typeManual drain
BracketSupplied without bracket
FluidCompressed air
Inlet pressure0 - 0.9 MPa (0 - 131 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GF400-10 Filter (GF40010MJW)

GF400G-series air filter, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain. Options are differential (blank), automatic (A) or manual (M).
JSupplied without bracket. A bracket ships by default; J orders it without.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF400 · PT3/8" · 5 µm
One size downGF300
One size upGF600
Line orderFilter first, then regulator, then lubricator

Where the AirTAC GF400-10 Filter (GF40010MJW) Is Used

science

Laboratory instrument air feed

Installed on the compressed-air line serving lab analysers and pneumatic sample handlers, the 5 um element keeps fine particulate out of instrument air ports and pilot circuits.

settings_input_component

Pilot-air supply to process valves

Mounted on the branch feeding positioner and pilot-air ports on a process-control valve skid, it screens condensate and fine debris that would foul small pilot orifices.

precision_manufacturing

CNC machine pallet-clamping air

Fitted before the clamping and tool-change circuits on a CNC machining centre, the fine element helps keep the small-bore clamping valves free of contamination between services.

Is the AirTAC GF400-10 Filter (GF40010MJW) the Right Filter?

Choose this code when you need three things at once: 400-size flow with a 3/8" PT port, the 5 um W element, and a bracket-less body for direct in-line plumbing. If your dirt load is coarse and general, the 40 um standard element costs less to run; reserve 5 um for cleaner duties or as the last filter before sensitive components. Manual drain means the bowl is bled by hand on a schedule. PT is the standard thread; G (BSPP) and NPT are catalogue options to order.

Sizing: flow is published as curves, not a single rating, so ask us to confirm the datasheet figures against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0 - 0.9 MPa (0 - 131 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 5 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

AirTAC GF400-10 Filter (GF40010MJW) FAQ

There is no single rated flow to quote: AirTAC publishes GF-series performance as flow curves. Share your line demand and we will confirm the datasheet figures on request, so you can verify the 400 frame and 3/8" port against your application before ordering.

The 40 um standard element suits general plant air with typical dirt loads; the W option's 5 um element is for duties feeding finer components such as pilot valves, instruments or precision cylinders. If you are unsure which grade your downstream equipment needs, tell us the application and we will help you choose.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GF400-10 Filter (GF40010MJW)

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GF40010MJW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.