The AirTAC Airtac 3V-F Base 3V200M8F is a genuine 3V-F manifold base manifold base for 8 stations on one shared air supply. A base is a machined block: it carries no coil and no solenoid, so the valves that sit on it are ordered separately.
The 3V200M8F is the eight-station manifold base for AirTAC's 3V200 body family. It is a machined block with PT internal threads and a single shared air connection: eight 3/2 solenoid valves bolt onto it side by side, each one feeding or venting its own outlet, while the supply port is drilled once for the whole row. Mounting the valves on one base means one air feed to design, one mounting footprint to plan and one block to unbolt during a strip-down.
We hold this base as a genuine AirTAC part and ship it on its own - the eight valves that sit on it are ordered separately, so you choose NC or NO, the coil voltage and the electrical entry for every position independently. Alongside this 8-station version we stock the wider family: other station counts, all five coil voltages, both entry styles, and individual valves from every body size. Pressure, flow and coil figures for this family are not published in our literature, so send us the RFQ and we will read them out of the datasheet for you before you commit.
| Model | Airtac 3V-F Base 3V200M8F |
|---|---|
| Series | 3V-F manifold base |
| Item form | Manifold base (no coil, no solenoid, no initial state) |
| Stations | 8 |
| Port size | Confirm from the datasheet — ask us |
| Thread | PT |
| Operating pressure | Confirm from the datasheet — ask us |
|---|---|
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V-F manifold base | Body. |
|---|---|
| 8F | 8 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A row of single-acting swing clamps on a jig table, each vented to exhaust independently between cycles. Eight stations on one base put the whole clamping circuit behind a single lockout point.
Belt-mounted air jets that puff containers off the rail and clear debris from guides. Each jet needs its own on/off valve, and one base keeps the plumbing to a single air drop.
A palletising robot cycling suction cups and spring-return grippers. Valves mounted on the cell manifold shorten the tubing runs and let a technician trace any station without following hoses.
Start by counting positions: this block carries exactly eight valves, so an eleven-clamp machine needs either two bases or the next station count up - ask us which sizes we hold. The valves themselves are not included. For each of the eight positions you pick the valve separately, which is worth doing deliberately: a fail-safe clamp position probably wants a normally closed valve while a continuously vented ejector position may want normally open, and there is no reason for the two to match. Because the coils are chosen per valve too, you can land every station on the same 24V DC control circuit, or mix voltages if a legacy panel demands it.
One honest caveat before you order. Our published figures for this family are not in hand, so we cannot confirm on this page which flow each station delivers to your actuator. Ask us to check the datasheet against the cylinder or blow-off duty before you buy. If you need a 3-port valve whose flow and coil power are documented right now, the AirTAC 3V2 and 3V3 bodies are the fully specified alternatives. And if any station has to drive a double-acting cylinder, a 3/2 valve cannot do it - that job belongs to the AirTAC 4V series.
Confirm before you order
We do not publish performance numbers for this family because the manufacturer's data is not in our current literature - not because the base lacks it. Tell us your supply pressure and the valves you plan to mount, and we will confirm the ratings from the datasheet. If you need published flow and coil-power figures printed on the page today, the AirTAC 3V2 (1/8in and 1/4in) and 3V3 (1/4in) bodies are the fully documented 3/2 alternatives.
No - the 3V200M8F is the machined block only, so budget eight valves separately. Every position is chosen independently: NC or NO depending on where that station must sit on power loss, the coil voltage to match your control circuit, and a DIN plug or flying-lead entry to suit the wiring. That also means the base itself has no coil and draws nothing; it is pipework, not an electrical component.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.