The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOEI-4F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The AirTAC 3V2MNOEI-4F mounts four normally open 3/2 valves on a single 4-station base, so one PT1/8 supply line and one wiring run cover the whole group. Each valve is direct-acting, spring-return and coaxial shut-off, with a Cv 0.1 flow path through the base. With the NO initial state, all four outlets feed air until their AC24V coils (7 VA each, on flying leads) are energised.
Exhaust is centralised: all four stations vent through the base instead of each carrying its own silencer, which keeps the manifold face clean and simplifies ducting on crowded machines. If your layout needs per-station venting instead, the same valves are offered as an independent-exhaust variant. The state cannot be reworked later - flipping the dedicated gasket does not turn NO into NC.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOEI-4F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 4 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 4F | 4 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Four spring-return gate cylinders on a bottling conveyor are fed while the line is idle; energising any coil vents its gate so a jam can be cleared at one point only.
Four large diaphragm process valves take their pilot signals from one 4-station block, cutting tubing runs and wiring points across the skid frame.
Four single-acting clamps around a stamping die hold the blank while coils are off; the operator energises one valve to release a single clamp for adjustment.
Match five points: normally open state (unchangeable after purchase), AC24V coil, flying-lead entry, 4 stations and centralised exhaust on a PT1/8 base - G and NPT threads exist as catalogue options to order. At Cv 0.1 the 3V2M wins on density; go to an individual 3V2 (Cv 0.18 at 1/8, 0.19 at 1/4, vacuum-rated) or a 3V3 (Cv 0.62 at 1/4, vacuum-rated) when a circuit wants more flow, or 3V1 (3.0 W DC) when coil load must stay minimal. Double-acting cylinders belong on the 5-port AirTAC 4V series.
Confirm before you order
Four 3/2 NO valves, Cv 0.1, operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, AC24V coils at 7 VA each, IP65 (DIN 40050), PT1/8 ports on a centralised-exhaust base.
This version vents all four stations through one centralised exhaust path on the base, which is tidy and easier to silence. If noise or mist must be kept away from neighbouring stations, order the -D independent-exhaust variant instead.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.