AirTAC 4V Series · 5/3-way Solenoid Valve

Airtac 4V Solenoid Valves 4V230E-08BT

The AirTAC Airtac 4V Solenoid Valves 4V230E-08BT is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with 08BT ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Exhaust center
  • Port size08BT
  • Effective area13.6 mm²
  • Flow (Cv)0.8
  • Series4V200
$57.78 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 4V Solenoid Valves 4V230E-08BT

The AirTAC 4V230E-08BT is a 5/3-way double-solenoid pneumatic directional valve built on the mid-flow 4V200 body. When both coils are de-energised, the spring-centered spool moves to the exhaust-center position: both cylinder ports A and B are connected to exhaust, allowing the double-acting actuator to float freely. This NPT-threaded model runs on a 3.0 W DC24V coil and is wired through a standard terminal box.

With an effective area of 13.6 mm² (Cv 0.8) and a maximum cycling speed of 3 cycles per second, it suits double-acting cylinders in the ~O32-50 mm range. The valve weighs 360 g, responds in 0.05 s or less, and carries an IP65 protection rating. Its aluminum-alloy body operates reliably from 0.15-0.8 MPa across a -20 to +70 °C temperature band.

Airtac 4V Solenoid Valves 4V230E-08BT Technical Specifications

ModelAirtac 4V Solenoid Valves 4V230E-08BT
Series4V200 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Exhaust center
Port size08BT
Exhaust port08BT
Effective area (Cv)13.6 mm² (Cv 0.8)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight360 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area13.6 mm²
Flow coefficientCv 0.8
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: Airtac 4V Solenoid Valves 4V230E-08BT

4VSolenoid valve, spool type, 4-series.
2Body size (4V200) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-08BTPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the Airtac 4V Solenoid Valves 4V230E-08BT Is Used

handyman

Manual Load/Unload Stations

De-energise both solenoids to exhaust both cylinder ports. The rod floats freely, letting an operator push or pull a fixture into place without fighting trapped air pressure.

precision_manufacturing

Two-Position Clamping with Free Center

Drive a clamp to two distinct positions using the solenoids. At center, the exhaust state releases all clamping force, simplifying part changeover on small assembly pallets.

conveyor_belt

Diverter Gates with Manual Override

Operate a diverter gate to two powered positions. In a jam or E-stop, the exhaust center lets an operator manually swing the gate clear without back-pressure resistance.

Is the Airtac 4V Solenoid Valves 4V230E-08BT the Right Valve?

Choose the 4V230E-08BT when your application needs a double-acting cylinder to go limp at mid-stroke—common in manual-load stations where an operator must push the rod freely. The exhaust-center spool vents both sides of the piston, so no trapped air resists external force. If you need the rod to hold position instead, switch to the closed-center 4V230C variant.

This NPT-thread, DC24V terminal-box model is a drop-in replacement for any 4V200-series 5/3 exhaust-center valve with the same port and voltage. For smaller O20-32 mm cylinders, the 4V100 series (Cv 0.6) reduces over-sizing; for larger O40-63 mm bores or faster strokes, step up to the 4V300 (Cv 1.65). When matching a replacement, confirm all five points: 4V200 body, 5/3 exhaust-center function, 1/4 NPT port, DC24V coil, and terminal-box entry.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

Airtac 4V Solenoid Valves 4V230E-08BT FAQ

Its 13.6 mm² effective area (Cv 0.8) pairs well with double-acting cylinders roughly O32-50 mm in bore. For a precise match, calculate the required Cv from your cylinder volume, stroke time, and operating pressure.

When neither solenoid is energised, internal springs center the spool and connect both cylinder ports (A and B) to the exhaust port. The actuator rod is unpressurised and can be moved by an external force—ideal for manual positioning, but never use this alone to hold a suspended load.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 4V Solenoid Valves 4V230E-08BT

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V230E-08BT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.