verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 4V Series · 5/2-way Solenoid Valve

AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006A-AM)

The AirTAC AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006A-AM) is a genuine 5/2-way single solenoid (spring return) solenoid valve with AM ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionSingle solenoid (spring return)
  • Port sizeAM
  • Effective area10.2 mm²
  • Flow (Cv)0.6
  • Series4V100
$30.93 $35.38Save 12% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V110-06 stroke, mounting and version on one page All 4V110-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006A-AM)

The 4V11006A-AM is the AirTAC 4V110 single-solenoid 5/2 valve in its AC220V, screw-terminal build, supplied from the factory with an AMISCO (Italian) solenoid coil in place of the standard coil. It directs compressed air to a double-acting cylinder or actuator: energise the coil and the spool shifts to pressurise one port while exhausting the other; de-energise and the return spring snaps the spool back to its rest position. Because the spring does the reset, the coil signal must stay on for as long as you want the cylinder extended.

In flow terms this is the entry size of the 4V family: an effective area of 10.2 mm2 (Cv 0.6) with cycling up to 5 cycles per second, so it pairs naturally with bores around O16-32 mm. The whole valve weighs just 120 g, switches in 0.05 s or less, and carries IP65 protection. The AMISCO coil changes the brand of the solenoid only - body, ports, function and flow are identical to the standard 4V110-06A; confirm the exact AMISCO coil rating for your AC220V supply with us when ordering.

AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006A-AM) Technical Specifications

ModelAirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006A-AM)
Series4V100 solenoid valve (spool type)
Valve type5/2-way
FunctionSingle solenoid (spring return)
Port sizeAM
Exhaust portAM
Effective area (Cv)10.2 mm² (Cv 0.6)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight120 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area10.2 mm²
Flow coefficientCv 0.6
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006A-AM)

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
1Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-AMPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006A-AM) Is Used

handyman

Small clamping fixtures

Spring return gives a fail-to-rest clamp or release on jig and fixture stations built around O16-32 mm double-acting cylinders, with Cv 0.6 keeping short-stroke clamp times tight.

precision_manufacturing

Pick-and-place grippers

The 0.05 s response and 5 cycle/sec rating suit light gripper cycling on compact assembly heads where the head must retreat whenever the coil signal drops.

build

Benchtop automation

At 120 g with 1/8in ports and a terminal-box AC220V connection, this valve drops neatly into lab rigs and small test benches wired straight to 220V control panels.

Is the AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006A-AM) the Right Valve?

Choose this model when your cylinder bore sits in the O16-32 mm band and a Cv 0.6 valve gives the speed you need. If the actuator is larger or the cycle needs to be quicker, step up one body size to the 4V200, which flows at Cv 1.0 on the same 1/8in porting. Prefer a valve that stays put through a power cut? The double-solenoid 4V120 is the memory version of this body; and if you need a mid-stroke hold, float or pressurise condition, the 5/3 4V130C/E/P variants cover those - note they flow less (Cv 0.51). A single valve suits one-off stations; screw a bank of them onto a manifold base when several cylinders share one air supply.

Replacing an existing unit? Match all five points: body size 4V100, function (single solenoid 5/2, spring return), port and thread (1/8in PT tapered), coil voltage (AC220V) and electrical entry (terminal box). The -AM suffix only affects the coil brand, so a standard 4V110-06A and this part are mechanically interchangeable.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006A-AM) FAQ

It is a 5/2 valve with an effective area of 10.2 mm2 (Cv 0.6), so it comfortably handles double-acting cylinders in the O16-32 mm range at practical speeds. It cannot drive single-acting cylinders - those need a 3/2 valve. For larger bores or faster strokes, move up to the 4V200 body (Cv 1.0).

It means the valve leaves the factory fitted with an AMISCO (Italian) solenoid coil instead of the standard AirTAC coil. The body, 5/2 spring-return function, 1/8in PT ports and Cv 0.6 flow are unchanged, and the coil is still ordered for AC220V with a terminal box. The AMISCO coil's exact VA rating is not in our published data, so ask us to confirm it for your supply before commissioning.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006A-AM)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V11006A-AM and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.