verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 4V Series · 5/2-way Solenoid Valve

AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM)

The AirTAC AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM) is a genuine 5/2-way single solenoid (spring return) solenoid valve with AM ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionSingle solenoid (spring return)
  • Port sizeAM
  • Effective area10.2 mm²
  • Flow (Cv)0.6
  • Series4V100
$30.93 $35.38Save 12% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V110-06 stroke, mounting and version on one page All 4V110-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM)

The 4V110-06E-AM is a 4V100-series 5/2-way single-solenoid valve built for switching double-acting cylinders and pneumatic actuators. Energise the coil and air flows to one cylinder port while the other exhausts; cut the signal and the internal spring snaps the spool back, reversing the stroke automatically. This particular SKU carries the factory -AM option: an AMISCO (Italian) solenoid coil fitted in place of the standard AirTAC coil, wired for a 24V AC supply through the built-in terminal box. Body, ports, function and flow are otherwise identical to the base 4V110-06E.

Flow sits in the light-duty class that fits the smallest AirTAC cylinder range: 10.2 mm2 effective area (Cv 0.6) is right for bores of roughly O16-32 mm. The valve reacts in 0.05 s or less, tolerates up to 5 cycles per second, weighs just 120 g, and runs on 0.15-0.8 MPa of clean air filtered to 40 um. If you need the exact electrical rating (VA) of the AMISCO coil on this AC24V unit, confirm it with us before ordering - we supply it on request.

AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM) Technical Specifications

ModelAirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM)
Series4V100 solenoid valve (spool type)
Valve type5/2-way
FunctionSingle solenoid (spring return)
Port sizeAM
Exhaust portAM
Effective area (Cv)10.2 mm² (Cv 0.6)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight120 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area10.2 mm²
Flow coefficientCv 0.6
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM)

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
1Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-AMPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM) Is Used

precision_manufacturing

Small pneumatic clamps

The 10.2 mm2 orifice (Cv 0.6) moves compact double-acting clamp cylinders quickly through their short stroke, and the spring return re-opens or re-closes the clamp the instant the AC24V signal drops.

build

Pick-and-place grippers

At 120 g the valve mounts directly on small handling stations, driving compact parallel grippers at up to 5 cycles per second with a 0.05 s or better response that keeps indexing tight.

science

Benchtop automation and test rigs

A 24V AC coil on a terminal box suits lab and prototype machines wired from control transformers, while the 1/8 PT ports accept standard fittings for O16-32 mm actuators on jigs and fixtures.

Is the AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM) the Right Valve?

Size check first: at Cv 0.6 this 4V100 body is the correct match for double-acting cylinders in the O16-32 mm band. If your actuator is larger or the cycle needs to be snappier, step up to the 4V200 family (Cv 1.0) rather than overspeeding a 4V110. For the directional logic itself: a single coil with spring return (this valve) is the safe choice when the cylinder must always park in one position on signal loss; a double-solenoid 5/2 (function 20) remembers its last position without holding current; and a 5/3 (function 30x) adds a defined center condition. Single units like this one can also be ganged onto a common base to build an integrated manifold group.

Replacing an existing valve? Match all five points: body size 4V100, function 10 (single solenoid, spring return), 1/8 port with PT thread, AC24V coil, terminal-box entry - plus the -AM AMISCO coil option if your original spec called for it.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM) FAQ

It is a 5/2-way valve with 10.2 mm2 effective area (Cv 0.6), which suits double-acting cylinders in the ~O16-32 mm bore range. It is not rated for single-acting cylinders - a 3/2 valve is the right type for those. For larger bores or faster cycles, move up to the 4V200 with its Cv 1.0.

-AM means the factory fitted an AMISCO (Italian) solenoid coil instead of the standard AirTAC coil; the valve function, 1/8 PT ports and flow are unchanged. This unit is wound for 24V AC - it is not a DC valve, so do not apply 24V DC. AirTAC does not publish the AMISCO coil's VA figure in the standard datasheet, so confirm the exact electrical rating with us before ordering.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V11006E-AM and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.