The AirTAC AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM) is a genuine 5/2-way single solenoid (spring return) solenoid valve with AM ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V110-06E-AM is a 4V100-series 5/2-way single-solenoid valve built for switching double-acting cylinders and pneumatic actuators. Energise the coil and air flows to one cylinder port while the other exhausts; cut the signal and the internal spring snaps the spool back, reversing the stroke automatically. This particular SKU carries the factory -AM option: an AMISCO (Italian) solenoid coil fitted in place of the standard AirTAC coil, wired for a 24V AC supply through the built-in terminal box. Body, ports, function and flow are otherwise identical to the base 4V110-06E.
Flow sits in the light-duty class that fits the smallest AirTAC cylinder range: 10.2 mm2 effective area (Cv 0.6) is right for bores of roughly O16-32 mm. The valve reacts in 0.05 s or less, tolerates up to 5 cycles per second, weighs just 120 g, and runs on 0.15-0.8 MPa of clean air filtered to 40 um. If you need the exact electrical rating (VA) of the AMISCO coil on this AC24V unit, confirm it with us before ordering - we supply it on request.
| Model | AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006E-AM) |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Single solenoid (spring return) |
| Port size | AM |
| Exhaust port | AM |
| Effective area (Cv) | 10.2 mm² (Cv 0.6) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 120 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 10.2 mm² |
|---|---|
| Flow coefficient | Cv 0.6 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 1 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -AM | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
The 10.2 mm2 orifice (Cv 0.6) moves compact double-acting clamp cylinders quickly through their short stroke, and the spring return re-opens or re-closes the clamp the instant the AC24V signal drops.
At 120 g the valve mounts directly on small handling stations, driving compact parallel grippers at up to 5 cycles per second with a 0.05 s or better response that keeps indexing tight.
A 24V AC coil on a terminal box suits lab and prototype machines wired from control transformers, while the 1/8 PT ports accept standard fittings for O16-32 mm actuators on jigs and fixtures.
Size check first: at Cv 0.6 this 4V100 body is the correct match for double-acting cylinders in the O16-32 mm band. If your actuator is larger or the cycle needs to be snappier, step up to the 4V200 family (Cv 1.0) rather than overspeeding a 4V110. For the directional logic itself: a single coil with spring return (this valve) is the safe choice when the cylinder must always park in one position on signal loss; a double-solenoid 5/2 (function 20) remembers its last position without holding current; and a 5/3 (function 30x) adds a defined center condition. Single units like this one can also be ganged onto a common base to build an integrated manifold group.
Replacing an existing valve? Match all five points: body size 4V100, function 10 (single solenoid, spring return), 1/8 port with PT thread, AC24V coil, terminal-box entry - plus the -AM AMISCO coil option if your original spec called for it.
Quick checklist
It is a 5/2-way valve with 10.2 mm2 effective area (Cv 0.6), which suits double-acting cylinders in the ~O16-32 mm bore range. It is not rated for single-acting cylinders - a 3/2 valve is the right type for those. For larger bores or faster cycles, move up to the 4V200 with its Cv 1.0.
-AM means the factory fitted an AMISCO (Italian) solenoid coil instead of the standard AirTAC coil; the valve function, 1/8 PT ports and flow are unchanged. This unit is wound for 24V AC - it is not a DC valve, so do not apply 24V DC. AirTAC does not publish the AMISCO coil's VA figure in the standard datasheet, so confirm the exact electrical rating with us before ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.