The AirTAC AirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W) is a genuine 5/2-way single solenoid (spring return) solenoid valve with W ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionSingle solenoid (spring return)
  • Port sizeW
  • Effective area28.0 mm²
  • Flow (Cv)1.65
  • Series4V300
$38.89 $43.55Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V310-10 stroke, mounting and version on one page All 4V310-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W)

The 4V31010FI-W is the external-pilot (-W) build of the AirTAC 4V300-series 5/2 single-solenoid valve. Energise the coil and pressurised air is directed to one side of a double-acting cylinder while the other side exhausts; cut the signal and the spring returns the spool to its rest position, so the valve needs a constant electrical signal to hold the advanced stroke. Because the -W option feeds pilot air through a separate external port rather than tapping it internally from the main line, the spool still shifts dependably on low main-line pressure and in vacuum or low-pressure circuits - a fit internal-pilot valves cannot always make.

This exact SKU pairs the 3/8in PT-tapered body (In/Out 3/8in, exhaust 1/4in) with a DC12V coil drawing 2.5 W and a grommet entry, so it arrives pre-wired with a roughly 0.5 m flying lead - no terminal-box wiring on the machine. Flow capacity sits at an effective area of 28.0 mm2 (Cv 1.65), a class that suits cylinders of roughly O50-80 mm bore. Switching response is 0.05 s or better and the valve weighs 310 g, keeping actuator manifolds light.

AirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W) Technical Specifications

ModelAirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W)
Series4V300 solenoid valve (spool type)
Valve type5/2-way
FunctionSingle solenoid (spring return)
Port sizeW
Exhaust portW
Effective area (Cv)28.0 mm² (Cv 1.65)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency4 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight310 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area28.0 mm²
Flow coefficientCv 1.65
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W)

4VSolenoid valve, spool type, 4-series.
3Body size (4V300) — sets port & flow.
1Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-WPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W) Is Used

factory

Low-pressure and vacuum circuits

External pilot supply lets the spool shift even when the main line is at low pressure or under vacuum, where internally piloted 5/2 valves fail to switch.

conveyor_belt

Larger-bore material handling

Cv 1.65 flow and a 4 cycle/sec rating drive O50-80 mm double-acting cylinders on pushers, lifts and diverters with sub-0.05 s response.

build

Clamping with fail-safe retraction

Spring return retracts the clamp automatically whenever the DC12V signal drops, and the 12 V 2.5 W grommet coil suits battery- or low-voltage-controlled machines.

Is the AirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W) the Right Valve?

Size first: at Cv 1.65 this body suits ~O50-80 mm bores. Step down to the 4V200 (Cv 1.0) for smaller cylinders or step up to the 4V400 (Cv 2.82) for larger ones. Function-wise, choose this single-solenoid spring-return type when a lost signal must retract the actuator; pick a double-solenoid 5/2 (memory) if the position should persist through power loss, or a 5/3 version when a defined center condition (closed, exhaust or pressure) is required. A single valve suits one actuator; add a manifold base when several valves share one supply. Specify the -W external-pilot variant whenever main-line pressure runs low or the circuit sees vacuum.

For a like-for-like replacement, match all five points: body size 4V300, function 10 (single 5/2 spring return), port and thread (3/8in PT - Rc tapered; G or T/NPT variants exist), coil voltage DC12V, and electrical entry grommet - plus the -W external-pilot suffix.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W) FAQ

It is a 5/2 single-solenoid valve for double-acting cylinders and actuators. With an effective area of 28.0 mm2 (Cv 1.65) and a 3/8in PT supply port, it suits bores of roughly O50-80 mm and switches up to 4 cycles per second with a response of 0.05 s or less. It is not rated for single-acting cylinders, which need a 3/2 valve.

The -W suffix means pilot air enters through a dedicated external port instead of being taken from the valve's own inlet, so switching stays reliable when main-line pressure is low or the circuit runs under vacuum. The F grommet coil runs on DC12V at 2.5 W and comes with a pre-wired lead (about 0.5 m), which saves terminal-box wiring on 12 V control systems.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V31010FI-W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.