The AirTAC AirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W) is a genuine 5/2-way single solenoid (spring return) solenoid valve with W ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V31010FI-W is the external-pilot (-W) build of the AirTAC 4V300-series 5/2 single-solenoid valve. Energise the coil and pressurised air is directed to one side of a double-acting cylinder while the other side exhausts; cut the signal and the spring returns the spool to its rest position, so the valve needs a constant electrical signal to hold the advanced stroke. Because the -W option feeds pilot air through a separate external port rather than tapping it internally from the main line, the spool still shifts dependably on low main-line pressure and in vacuum or low-pressure circuits - a fit internal-pilot valves cannot always make.
This exact SKU pairs the 3/8in PT-tapered body (In/Out 3/8in, exhaust 1/4in) with a DC12V coil drawing 2.5 W and a grommet entry, so it arrives pre-wired with a roughly 0.5 m flying lead - no terminal-box wiring on the machine. Flow capacity sits at an effective area of 28.0 mm2 (Cv 1.65), a class that suits cylinders of roughly O50-80 mm bore. Switching response is 0.05 s or better and the valve weighs 310 g, keeping actuator manifolds light.
| Model | AirTAC 4V310-10 Solenoid Valve, 4V300 Series (4V31010FI-W) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Single solenoid (spring return) |
| Port size | W |
| Exhaust port | W |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 310 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 1 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -W | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
External pilot supply lets the spool shift even when the main line is at low pressure or under vacuum, where internally piloted 5/2 valves fail to switch.
Cv 1.65 flow and a 4 cycle/sec rating drive O50-80 mm double-acting cylinders on pushers, lifts and diverters with sub-0.05 s response.
Spring return retracts the clamp automatically whenever the DC12V signal drops, and the 12 V 2.5 W grommet coil suits battery- or low-voltage-controlled machines.
Size first: at Cv 1.65 this body suits ~O50-80 mm bores. Step down to the 4V200 (Cv 1.0) for smaller cylinders or step up to the 4V400 (Cv 2.82) for larger ones. Function-wise, choose this single-solenoid spring-return type when a lost signal must retract the actuator; pick a double-solenoid 5/2 (memory) if the position should persist through power loss, or a 5/3 version when a defined center condition (closed, exhaust or pressure) is required. A single valve suits one actuator; add a manifold base when several valves share one supply. Specify the -W external-pilot variant whenever main-line pressure runs low or the circuit sees vacuum.
For a like-for-like replacement, match all five points: body size 4V300, function 10 (single 5/2 spring return), port and thread (3/8in PT - Rc tapered; G or T/NPT variants exist), coil voltage DC12V, and electrical entry grommet - plus the -W external-pilot suffix.
Quick checklist
It is a 5/2 single-solenoid valve for double-acting cylinders and actuators. With an effective area of 28.0 mm2 (Cv 1.65) and a 3/8in PT supply port, it suits bores of roughly O50-80 mm and switches up to 4 cycles per second with a response of 0.05 s or less. It is not rated for single-acting cylinders, which need a 3/2 valve.
The -W suffix means pilot air enters through a dedicated external port instead of being taken from the valve's own inlet, so switching stays reliable when main-line pressure is low or the circuit runs under vacuum. The F grommet coil runs on DC12V at 2.5 W and comes with a pre-wired lead (about 0.5 m), which saves terminal-box wiring on 12 V control systems.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.