Airtac 4V210-08 Solenoid Valves and Related 4V21008 Models
Find Airtac 4V210-08 pneumatic solenoid valves and related 4V21008 models for air cylinder control, actuator automation, packaging equipment, machine tools and general pneumatic systems. This page helps you compare 4V210-08 valve types, coil voltage options, port sizes, working principles, technical specifications, ordering codes and downloadable catalogs.
Product Key Features
5/2 Way
Directional Control Valve
1/4" Port Size
Compact & Efficient Layout
Multiple Coil Voltage Options
DC12V • DC24V • AC110V • AC220V • AC24V
Manual Override
Easy Installation & Commissioning
Suitable for Cylinders
Designed for Pneumatic Cylinders & Actuators
Technical Assets Available
Catalog & Datasheet Instantly Available
Airtac 4V210-08 Solenoid Valve Product List
Browse Airtac 4V210-08 and related 4V21008 solenoid valves by voltage, coil type, thread option and configuration. If you are replacing an existing valve, check the model code, port size, coil voltage and wiring connection before ordering.
Can’t find the exact Airtac 4V210-08 solenoid valve you need?
Contact us with your model number, coil voltage, port size or application. Our team will help you find the right Airtac 4V210-08 or related 4V200 series valve. Click Here to Contact Us for Model Selection
What Is an Airtac 4V210-08 Solenoid Valve?
The Airtac 4V210-08 is a pneumatic directional control solenoid valve from the Airtac 4V200 series. It is commonly used to control the extension and retraction of double-acting pneumatic cylinders by directing compressed air to different ports. The 4V210-08 is typically selected for compact automation systems that require a 5-port, 2-position valve with a 1/4 inch port size.
In practical applications, the valve receives an electrical signal from a PLC, relay, switch or controller. When the coil is energized, the internal spool shifts and changes the airflow path. This allows the valve to control pneumatic actuators in equipment such as packaging machines, assembly lines, conveyors, fixtures, machine tools and general industrial automation systems.
Airtac 4V210-08 Model Number Meaning
| Code | Meaning |
|---|---|
| 4V | Airtac 4V series pneumatic solenoid valve |
| 2 | 200 series body size |
| 10 | Single solenoid, 2-position configuration |
| 08 | 1/4 inch port size |
| Voltage suffix | Coil voltage such as DC24V, AC110V, AC220V, DC12V or AC24V |
| Thread suffix | Thread type, depending on market and configuration |
Airtac 4V210-08 Technical Specifications
The 4V210-08 is part of the Airtac 4V200 series and is designed for pneumatic directional control. It is commonly used with filtered compressed air and can be installed as a single valve or integrated with a manifold base to save installation space.
Before ordering, always confirm the port thread, coil voltage, connector style and operating pressure range required by your pneumatic system.
| Specification | 4V210-08 Reference Information |
|---|---|
| Series | Airtac 4V200 Series |
| Valve Type | 5-port, 2-position solenoid valve |
| Control Type | Single solenoid |
| Port Size | 1/4 inch |
| Working Medium | Filtered compressed air |
| Coil Voltage Options | DC24V, DC12V, AC110V, AC220V, AC24V |
| Manual Override | Available |
| Lubrication | Usually not required; keep consistent if lubricated air is used |
| Mounting | Individual mounting or manifold/base mounting |
| Application | Pneumatic cylinder and actuator control |
How Does the Airtac 4V210-08 Solenoid Valve Work?
| Port | Function |
|---|---|
| P | Air supply / inlet |
| A | Working port to actuator |
| B | Working port to actuator |
| R | Exhaust port |
| S | Exhaust port |
How to Choose the Correct 4V210-08 Solenoid Valve
-
1Confirm the coil voltage:
DC24V, AC110V, AC220V, DC12V or AC24V -
2Confirm the port size: 08 usually indicates 1/4 inch port size.
-
3Check the thread type: PT, NPT or G may vary by market.
-
4Confirm the valve function: 5/2 way, single solenoid.
-
5Check the connector type and wiring method.
-
6Verify the working pressure and temperature range.
-
7Confirm whether a manifold base or individual mounting is required.
Installation and Usage Notes
Before installation, inspect the valve for shipping damage and confirm that the model, voltage and port thread match your system requirements. Use clean, filtered compressed air and follow the indicated airflow direction on the valve body.
For best performance, keep fittings and tubes clean during assembly, avoid excessive thread seal tape, and prevent dust or metal chips from entering the valve. Exhaust ports should be protected with silencers or suitable exhaust fittings where required.
Common Applications of Airtac 4V210-08 Valves
- Pneumatic cylinder control
- Automated packaging machines
- Conveyor sorting systems
- Machine tool fixtures
- Assembly line automation
- Air-operated clamps
- Pick-and-place systems
- Industrial control panels
Airtac 4V210-08 Datasheet, Catalog and Manual Downloads
Technical Documents & Manuals
- Airtac 4V200 Series Solenoid Valve Catalog PDF
- Airtac 4V210-08 Technical Datasheet
- 4V200 Series Ordering Code Guide
- 4V200 Series Installation and Usage Instructions
- 4V210-08 Dimension Drawing
- 4V210-08 Wiring and Coil Information