The AirTAC 3V1 Solenoid Valve 3V106EI5FT is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
3V106EI5FT packs five 3/2 direct-acting valves into a single five-station 3V1 manifold on a 1/8 in NPT base. Each coil runs AC24V at 3.0 W and leaves the block as a flying lead, so the whole assembly wires with flexible leads rather than plug-in connectors. Spring return means every station reverts to its rest state as soon as power is removed.
Because a 3/2 valve has three ports and two states, each of the five stations either feeds its line or vents it to exhaust - the pattern behind single-acting cylinders, clamps, blow and pilot duty. Coil housings are IP65 (DIN 40050), a manual override aids commissioning, and the air supply needs only 40 um filtration. Each valve is supplied in a single fixed initial state - check it on the datasheet.
| Model | Airtac 3V1 Solenoid Valve 3V106EI5FT |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | 1/8 in |
| Thread | NPT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 5.0 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 5F | 5 stations in one assembly. |
| NPT | Port thread. PT is standard; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Five kick cylinders divert cartons between lanes on a packaging line, each one a single-acting unit fed and vented by its own station.
Five swing clamps on a weld fixture share one NPT1/8 manifold; the spring return drops every clamp safely when the AC24V coil de-energises.
Small single-acting lift cylinders on a high-cycle pick station cycle on 3.0 W coils, with no pilot air needed to reset them.
Since AirTAC lists no flow coefficient for 3V1, flow-sensitive applications should be checked against the duty before ordering. To gain capacity, move up to 3V2 - 1/8 in and 1/4 in ports, NC or NO selectable, Cv 0.18-0.19, vacuum rated - or to 3V3, a 1/4 in body with Cv 0.62. Where manifold density beats flow, 3V2M is the body designed for it. A double-acting cylinder sits outside a 3-port valve's reach, so route that requirement to the 5-port AirTAC 4V series.
Five details fix the order: M5 or 1/8 in port; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. coil voltage; DIN plug versus flying-lead entry; and whether you want an individual valve or a multi-station manifold of up to 20 stations.
Confirm before you order
The assembly works from 0 to 0.8 MPa (0-114 psi) across -20 to 70 C, with IP65 (DIN 40050) coils. Power draw by voltage option: AC220V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA, AC24V 3.0 W, DC12V 2.5 W - each of the five stations here carries the 3.0 W AC24V coil. No flow coefficient or effective area exists in the 3V1 catalogue data, so ask us for flow-critical sizing.
Yes. The 3V1 code structure offers five voltages (A = AC220V, B = AC24V, C = AC110V, E = AC24V, F = DC12V), DIN plug or flying-lead entry, and manifolds from 1F to 20F. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Tell us the segments you need and we will quote the matching assembly.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.