The AirTAC 3V106E-17 Solenoid Valve, 3V1 Series (3V106E17FT) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Seventeen 3V1 3/2 sections on one base make the 3V106E17FT a compact alternative to wiring seventeen separate valves. Direct-acting and single-solenoid, each section feeds or vents its line and springs back when de-energised, so it drives single-acting cylinders, clamps, blow-off jets or pilots a larger valve.
This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Coil protection is IP65 (DIN 40050), every valve carries a manual override, and the medium should be filtered to 40 um or finer with no lubrication required.
| Model | AirTAC 3V106E-17 Solenoid Valve, 3V1 Series (3V106E17FT) |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | 1/8 in |
| Thread | NPT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 5.0 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 17F | 17 stations in one assembly. |
| NPT | Port thread. PT is standard; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Single-acting stopper cylinders that pause totes between conveyor zones, each fed and vented by its own 3/2 section so loads release cleanly on power loss.
Compact single-acting lift and clamp actuators on an automated test bench, driven section by section with manual overrides for debugging a cycle.
Short-burst air pulses to cutter and kicker cylinders on a weaving line, switched at seventeen stations from one shared NPT1/8 supply.
Check flow before choosing a seventeen-station 3V1 bank: AirTAC publishes no Cv for the 3V1, so confirm any flow-critical duty with us first. Where 1/8 or 1/4 ports need more capacity, the 3V2 (NC or NO selectable, Cv 0.18-0.19, vacuum rated) or the 1/4-port 3V3 (Cv 0.62) are the natural steps up; 3V2M wins when manifold density, not flow, is the priority.
This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Double-acting cylinders need the AirTAC 4V series, not this 3/2 body.
Confirm before you order
Start with the envelope: 0-0.8 MPa (0-114 psi) operating pressure, -20 to 70 C media temperature, IP65 (DIN 40050) coils, and 4.5 VA per AC24V section. The 3V1 coil table is AC24V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA, DC24V 3.0 W, DC12V 2.5 W. The flow coefficient is not published for this body - send flow-critical duties to us for confirmation.
The 3V106E17FT uses DIN plug sockets, so valves unclip from the manifold for service and wiring runs through plug connectors. The 3V1 family also offers an I-suffix flying-lead entry with pre-wired lead-out wires - pick that when the sockets are hard to reach. Either way the coil here is AC24V at 4.5 VA and rated IP65 with the plug fitted.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.