verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2 · 3/2-Way Solenoid Valve

Airtac 3V2 Solenoid Valve 3V208NCCT

The AirTAC 3V2 Solenoid Valve 3V208NCCT is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/4 in
  • Coil voltageAC110V
  • Electrical entryDIN plug (DIN socket type)
  • Flow (Cv)0.19
  • Series3V2
$48.60 $56.10Save 13% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every 3V2-08 voltage, entry and configuration on one page All 3V2-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac 3V2 Solenoid Valve 3V208NCCT

The AirTAC 3V208NCCT is a 3/2-way solenoid valve in the normally closed (NC) configuration: its 1/4in NPT outlet stays closed until the AC110V coil is energised, then the valve feeds the line and vents it back to exhaust when the coil drops. Because it is direct-acting with a spring return, it shifts reliably at 0 MPa and needs no minimum pilot pressure.

A coaxial poppet inside the body gives tight shut-off and a per-port flow of Cv 0.19 (3.4 mm2 effective area). The valve also carries a negative-pressure rating of -102.2 kPa to 0.1 MPa, so one valve type can serve both vacuum and pressure circuits on the same machine. A manual override is fitted to help installation and commissioning.

Airtac 3V2 Solenoid Valve 3V208NCCT Technical Specifications

ModelAirtac 3V2 Solenoid Valve 3V208NCCT
Series3V2
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Port size1/4 in
ThreadNPT
Coil voltageAC110V
Electrical entryDIN plug (DIN socket type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceRated -102.2 kPa to 0.1 MPa
Flow coefficientCv 0.19 (3.4 mm2 effective area)
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), direct-acting, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Model Code: Airtac 3V2 Solenoid Valve 3V208NCCT

3V2Body — sets the flow, the coil power and whether vacuum is rated.
1/4 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
AC110VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
NPTPort thread. PT is standard; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2 Solenoid Valve 3V208NCCT Is Used

valve

Vacuum sheet lifting on a CNC router

Switches vacuum to cup modules holding MDF sheets; the -102.2 kPa rating lets one valve handle both the vacuum draw and the pressure blow-off release.

bolt

Pneumatic clamp on an assembly fixture

Energise to clamp, de-energise to vent the single-acting clamp cylinder through the exhaust port - the spring return gives a fail-vented rest state.

settings_input_component

Pilot stage for a large process valve

AC110V matches common control voltage; the NC state keeps the pilot line vented until deliberately triggered, and the manual override aids setup.

Is the Airtac 3V2 Solenoid Valve 3V208NCCT the Right Part?

Choose this code when you need 1/4in NPT ports, a normally closed start state, an AC110V coil and a DIN plug connection - all five points must match your drawing. If the duty is small and coil economy matters, the 3V1 series runs 3.0 W on DC24V instead of the 7 VA here; if you are ganging many stations and can trade flow, the base-mounted 3V2M (Cv 0.1) saves space through a manifold. When Cv 0.19 is simply not enough, step up to the 3V3 on 1/4in ports with Cv 0.62, which is also vacuum-rated.

Need to drive a double-acting cylinder? A 3/2 valve cannot - that requires a 5-port AirTAC 4V valve.

Confirm before you order

  • ✓ Port size and thread (PT standard; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2 Solenoid Valve 3V208NCCT FAQ

Port: 1/4in NPT, effective area 3.4 mm2 per port, Cv 0.19 (the 1/8in 3V206 gives 3.2 mm2 / Cv 0.18). Operating pressure 0-0.8 MPa; the body is also vacuum-rated from -102.2 kPa to 0.1 MPa. Temperature range -20 to 70 C. Coil: AC110V here, 7 VA for AC types and 7.0 W for DC types. Protection IP65 (DIN 40050).

No. A 3/2 valve has three ports and two states, so it either feeds a single line or vents it - correct for single-acting spring-return cylinders, blow-off, clamps and pilot duty. A double-acting cylinder needs supply and exhaust on both sides, which is the job of a 5-port valve such as the AirTAC 4V series.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac 3V2 Solenoid Valve 3V208NCCT

Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for 3V208NCCT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.