The AirTAC 3V2 Solenoid Valve 3V208NOBT is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
This is the DC24V DIN-plug version of the AirTAC 3V208 in its normally open form. As a 3/2-way valve it has three ports and two states: in the rest position the 1/4in inlet is already connected to the outlet, and energising the coil shuts the flow and vents the downstream line to exhaust. A spring returns the poppet the moment power is cut, so the de-energised condition is always the open one.
The coaxial poppet is direct-acting, so it needs no minimum pressure to seal and works from 0 to 0.8 MPa. Flow through each port is Cv 0.19 with a 3.4 mm2 effective area, and because the coil draws only 7.0 W on DC24V it suits battery-fed or low-voltage control panels. The valve is also rated for negative pressure down to -102.2 kPa, so the same body can switch vacuum circuits. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac 3V2 Solenoid Valve 3V208NOBT |
|---|---|
| Series | 3V2 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Port size | 1/4 in |
| Thread | NPT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Rated -102.2 kPa to 0.1 MPa |
| Flow coefficient | Cv 0.19 (3.4 mm2 effective area) |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), direct-acting, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| NPT | Port thread. PT is standard; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
On a bottling line the nozzles must blow continuously and stop only when the PLC commands it - the NO rest state keeps air flowing to the jets until the DC24V coil is energised.
A bank of spring-return clamps that must sit open by default can be fed through this valve; energising the 24V coil vents the clamp line and lets the springs drop the arms.
A larger actuated diaphragm valve on a filtration skid needs a small, reliable pilot; the 1/4in port and Cv 0.19 give enough volume to stroke the actuator briskly.
This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Size down to the 3V1 when the flow is small and coil power matters more - its DC24V coil takes 3.0 W against the 7.0 W here. Choose the 3V2M only when a dense multi-station manifold outweighs flow, since its base routing drops Cv to about 0.1. Step up to the 3V3 (Cv 0.62, also vacuum-rated) when the line needs far more than this valve passes. A double-acting cylinder cannot be run from any 3-port valve - that needs a 5-port AirTAC 4V.
Confirm before you order
Both port sizes share one set of figures: the 1/8in 3V206 gives 3.2 mm2 effective area and Cv 0.18 per port, the 1/4in 3V208 gives 3.4 mm2 and Cv 0.19. Pressure range is 0-0.8 MPa, and the valve is vacuum-rated to -102.2 kPa to 0.1 MPa. Working temperature is -20 to 70 C. Coils take 7 VA on AC and 7.0 W on DC, and protection is IP65 (DIN 40050).
Pick normally open when the outlet must receive air while the coil is off - continuous blow, purge or a fail-open vent - and switch flow off by energising. NC is the opposite: no air reaches the outlet until the coil is powered. With this 3V208NOBT the DC24V, DIN-plug form is fixed by the ordering code itself, so the code states the whole configuration.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.