verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2 · 3/2-Way Solenoid Valve

Airtac 3V2 Solenoid Valve 3V208NOCIT

The AirTAC 3V2 Solenoid Valve 3V208NOCIT is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/4 in
  • Coil voltageAC110V
  • Electrical entryFlying lead (lead-out wire type)
  • Flow (Cv)0.19
  • Series3V2
$43.98 $51.48Save 14% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every 3V2-08 voltage, entry and configuration on one page All 3V2-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac 3V2 Solenoid Valve 3V208NOCIT

Built for vacuum circuits that also need pre-wired wiring, the 3V208NOCIT pairs the normally open 1/4in 3V2 body with a flying-lead coil rated at AC110V (7 VA). The lead-out wires arrive ready to land on your terminals, avoiding a loose DIN plug inside a moving machine or a cramped cabinet. Three ports, two positions: at rest the vacuum or supply line is connected through, and energising the solenoid cuts the path while venting the outlet to exhaust. Spring return is built in.

The coaxial poppet is direct-acting and holds from -102.2 kPa vacuum up to 0.8 MPa, a negative-pressure rating the 3V1 and 3V2M bodies do not carry. Flow per port is Cv 0.19 with 3.4 mm2 effective area. Use air filtered to 40 um or finer; lubrication is not required. This version has NPT ports (the T in the order code) for North American pipe fittings.

Airtac 3V2 Solenoid Valve 3V208NOCIT Technical Specifications

ModelAirtac 3V2 Solenoid Valve 3V208NOCIT
Series3V2
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Port size1/4 in
ThreadNPT
Coil voltageAC110V
Electrical entryFlying lead (lead-out wire type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceRated -102.2 kPa to 0.1 MPa
Flow coefficientCv 0.19 (3.4 mm2 effective area)
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), direct-acting, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Model Code: Airtac 3V2 Solenoid Valve 3V208NOCIT

3V2Body — sets the flow, the coil power and whether vacuum is rated.
1/4 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
AC110VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
NPTPort thread. PT is standard; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2 Solenoid Valve 3V208NOCIT Is Used

build

CNC router hold-down

A vacuum table on a CNC router keeps the spoilboard clamped whenever power is off; the NO valve maintains the vacuum path at rest and the energised coil vents it to release the finished sheet.

local_shipping

Palletiser vacuum cups

On a palletising cell a suction frame lifts cartons; each zone's vacuum line runs through this valve, so a zone can be dropped at the pallet by energising its AC110V coil.

bolt

Fixture clamp release

Pneumatic swing clamps on a machining fixture stay fed at rest; landing the flying-lead wires on the PLC output lets the controller vent the clamp line the instant a cycle needs the part free.

Is the Airtac 3V2 Solenoid Valve 3V208NOCIT the Right Part?

This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. When less flow and lower coil draw would do, the 3V1 runs at 3.0 W on DC24V; when station density on a shared base beats flow, the 3V2M gives roughly Cv 0.1 per station through its manifold. For a genuine flow increase, jump to the 3V3 - its 1/4in Cv 0.62 is several times this valve, whereas the 1/8in to 1/4in move inside the 3V2 range alone lifts Cv only from 0.18 to 0.19. Double-acting cylinders are outside 3-port territory; specify the AirTAC 4V series for those.

Confirm before you order

  • ✓ Port size and thread (PT standard; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2 Solenoid Valve 3V208NOCIT FAQ

Effective area and Cv per port: 1/8in 3V206 = 3.2 mm2 and Cv 0.18; 1/4in 3V208 = 3.4 mm2 and Cv 0.19. Operating pressure 0-0.8 MPa; vacuum rating -102.2 kPa to 0.1 MPa. Temperature -20 to 70 C. Coil power 7 VA (AC) or 7.0 W (DC); this AC110V flying-lead coil is the 7 VA case. Protection IP65 (DIN 40050). Air should be filtered to 40 um or finer.

With NO the connection exists while the coil is off, so a power cut leaves the vacuum holding or the clamp fed - a fail-safe condition for hold-down and clamp lines. NC would drop the vacuum the moment power fails. If instead you need flow only while energised, order the NC version of the same body; the state is fixed by the ordering code.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac 3V2 Solenoid Valve 3V208NOCIT

Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for 3V208NOCIT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.