The AirTAC 3V3 Solenoid Valve 3V308NCEIT is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
3V308NCEIT is specified around its wiring: the AC24V coil leaves the factory on a flying lead, a pre-attached lead-out that removes the separate DIN connector from the bill of materials on machines where every valve is hard-wired anyway. On air, it is a normally closed 3/2 valve - supply, outlet, exhaust - with the outlet held closed by the spring and the coaxial poppet until the 10 VA coil pulls it open.
The body itself is the highest-flow 3-port unit AirTAC lists at Cv 0.62, and its sealing approach suits negative-pressure work: the valve is rated for vacuum duty from -102.2 kPa up to 0.1 MPa. Temperature envelope is -20 to 70 C, and the IP65 (DIN 40050) build keeps dust and splashes off the coil. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac 3V3 Solenoid Valve 3V308NCEIT |
|---|---|
| Series | 3V3 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Port size | 1/4 in |
| Thread | NPT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 10 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Rated -102.2 kPa to 0.1 MPa |
| Flow coefficient | Cv 0.62 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), direct-acting, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V3 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V3 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| NPT | Port thread. PT is standard; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Applies and releases vacuum to a wide multi-cup head that lifts flat corrugated blanks, with the poppet sealing reliably at -102.2 kPa and direct lead wiring to the machine harness.
Controls a spring-return gripper finger on a palletiser, where the NC state keeps the grip released and vented whenever the 24V AC control signal drops.
Feeds a hold-down cylinder and purge jet in a robotic weld cell, wired point-to-point on its flying lead and protected to IP65 against weld-spatter dust.
This is the top of AirTAC's 3-port ladder, so look down the range when the duty is smaller. 3V2 (Cv 0.18-0.19, also vacuum-rated) covers lighter lines, 3V2M (Cv 0.1) suits a crowded multi-station manifold where flow is not the constraint, and 3V1 handles the smallest low-power jobs (3.0 W on DC24V). Line up five parameters when ordering: port and thread (NPT on this code), initial state (NC on this code), coil voltage (AC24V), electrical entry (flying lead, not DIN plug), and whether vacuum appears anywhere in the duty. A double-acting cylinder belongs on a 5-port 4V valve, not here.
Confirm before you order
Cv 0.62 flow coefficient, pressure range 0-0.8 MPa (0-114 psi), vacuum rating -102.2 kPa to 0.1 MPa, temperature -20 to 70 C, coil power 10 VA (AC) or 6.5 W (DC), protection class IP65 (DIN 40050). It is a direct-acting, single-solenoid 3/2 valve with spring return on a 1/4in NPT port; the air supply should pass a 40 um or finer filter, with no lubrication required.
The I suffix replaces the DIN socket with a factory-fitted lead-out wire, so the coil is wired straight into the machine's control cabinet without buying or keeping separate DIN plugs. It makes sense on OEM machines and cells where every solenoid is hard-wired; if your panel prefers plug-in coils and quick swap-outs, the plain 3V308NCE with its DIN plug is the better match.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.