The AirTAC 3V3 Solenoid Valve 3V308NOCIT is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Wiring is what sets the 3V308NOCIT apart: a normally open 3/2 solenoid valve with a 1/4 inch NPT port and an AC110V coil on a flying lead, so the coil arrives pre-terminated for direct connection to a machine harness instead of sitting on a DIN socket. At rest the valve passes air from supply to outlet; energising the coil closes that path and vents the line to exhaust.
Underneath, it is the same coaxial poppet body as the rest of the 3V3 family: direct-acting, single solenoid with spring return, a Cv of 0.62 that tops the 3V range, a 0-0.8 MPa working range and a vacuum rating of -102.2 kPa to 0.1 MPa. The AC110V coil draws 10 VA. One line in, one outlet, one exhaust — so it suits single-acting cylinders, blow-off, clamps and pilot duty, but a double-acting cylinder needs a 5-port 4V valve.
| Model | Airtac 3V3 Solenoid Valve 3V308NOCIT |
|---|---|
| Series | 3V3 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Port size | 1/4 in |
| Thread | NPT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 10 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Rated -102.2 kPa to 0.1 MPa |
| Flow coefficient | Cv 0.62 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), direct-acting, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V3 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V3 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| NPT | Port thread. PT is standard; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A flying-lead coil drops straight into the existing control wiring of an older palletiser cell, adding a normally open vent path that a safety PLC can close on demand.
Feeds product-feed air to a filling head that must run whenever the line is idle and cut off the moment the controller energises the coil.
Pilots a larger diaphragm process valve that should stay open through a control-power failure; energising the 3V308NOCIT closes the pilot and shuts the process line.
Because the 3V3 body is already the biggest and freest-flowing 3-port valve AirTAC lists, sizing only ever steps down. Choose a 3V2 (Cv 0.18-0.19, 1/8 or 1/4 port, vacuum-rated too) when Cv 0.62 is overkill, a 3V2M (Cv 0.1) when a compact multi-station manifold beats raw flow, or a 3V1 (3.0 W on DC24V) for the tiniest low-power jobs. Tick five boxes: port and thread (NPT on this code), initial state — this code is NO — coil voltage (AC110V), electrical entry (flying lead here; drop the I for a DIN plug), and any vacuum requirement. Double-acting cylinders belong on the 4V series.
Confirm before you order
Flow coefficient Cv 0.62, working pressure 0-0.8 MPa, vacuum rating -102.2 kPa to 0.1 MPa, media and ambient temperature -20 to 70 C, AC coil power 10 VA (the DC builds in this family draw 6.5 W), IP65 protection to DIN 40050, 1/4 inch NPT port, 3/2-way normally open function.
Cv 0.62 is roughly three times the 0.19 of a 3V208 and about six times the 0.1 of a base-mounted 3V2M, so on a 1/4 inch line with a flow-hungry duty, the 3V3 is the body to pick. If the duty needs only a trickle, stepping down to a 3V2 or 3V2M saves panel space and cost.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.