verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V3 · 3/2-Way Solenoid Valve

Airtac 3V3 Solenoid Valve 3V308NOEIT

The AirTAC 3V3 Solenoid Valve 3V308NOEIT is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/4 in
  • Coil voltageAC24V
  • Electrical entryFlying lead (lead-out wire type)
  • Flow (Cv)0.62
  • Series3V3
$65.76 $73.26Save 10% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every 3V3-08 voltage, entry and configuration on one page All 3V3-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac 3V3 Solenoid Valve 3V308NOEIT

Circuits that run below atmospheric pressure are where the 3V308NOEIT earns its place: the same body that takes 0-0.8 MPa of compressed air is rated for vacuum service from -102.2 kPa to 0.1 MPa. It is a normally open 3/2 valve, so the 1/4 inch NPT port passes air or vacuum from supply to outlet at rest, and the energised AC24V coil shuts the path and vents the line.

The coil comes on a flying lead for direct harness connection rather than a DIN socket. Direct-acting, spring-return and built around a coaxial poppet, it delivers a Cv of 0.62 — the highest in the 3V range — which pays off with larger vacuum cups and longer eject lines. IP65 coil protection (DIN 40050) keeps it sealed in washdown-prone cells.

Airtac 3V3 Solenoid Valve 3V308NOEIT Technical Specifications

ModelAirtac 3V3 Solenoid Valve 3V308NOEIT
Series3V3
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Port size1/4 in
ThreadNPT
Coil voltageAC24V
Electrical entryFlying lead (lead-out wire type)
Coil power10 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceRated -102.2 kPa to 0.1 MPa
Flow coefficientCv 0.62
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), direct-acting, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V3 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Model Code: Airtac 3V3 Solenoid Valve 3V308NOEIT

3V3Body — sets the flow, the coil power and whether vacuum is rated.
1/4 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
AC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
NPTPort thread. PT is standard; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V3 Solenoid Valve 3V308NOEIT Is Used

speed

Gantry vacuum pick-and-place

Switches vacuum to a large suction cup on a pick-and-place gantry; the normally open path holds the part if control power is lost, and energising the coil releases it in a controlled vent.

view_module

Multi-cup plate lifter

Feeds one zone of a multi-cup array lifting sheet steel, where the 0.62 Cv keeps flow losses low across long vacuum lines to the outermost cups.

engineering

Vacuum test bench

Connects and vents a vacuum reservoir on a leak-test rig wired at AC24V, with the flying lead terminating straight at the bench controller.

Is the Airtac 3V3 Solenoid Valve 3V308NOEIT the Right Part?

Nothing in the 3-port range sits above the 3V3 on flow, so sizing means stepping down when Cv 0.62 is more than needed: to a 3V2 (1/8 or 1/4 port, Cv 0.18-0.19, also vacuum-rated), to a 3V2M (Cv 0.1) when a compact multi-station manifold matters more than flow, or to a 3V1 for the smallest low-power jobs (3.0 W on DC24V). Before ordering, settle five things: port and thread (NPT on this code), initial state (this code is NO), coil voltage (AC24V), electrical entry (flying lead here; remove the I for a DIN plug), and whether the duty includes vacuum — this body does. For double-acting cylinders, go to the 4V series.

Confirm before you order

  • ✓ Port size and thread (PT standard; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V3 Solenoid Valve 3V308NOEIT FAQ

Flow coefficient Cv 0.62, pressure range 0-0.8 MPa, vacuum rating -102.2 kPa to 0.1 MPa, temperature -20 to 70 C, 10 VA on the AC24V coil (DC builds of this family take 6.5 W), IP65 protection to DIN 40050, 1/4 inch NPT port, 3/2-way normally open function.

Pick NO when the outlet must stay fed — or the vacuum cup must stay loaded — while the coil is off, so a power failure leaves the process in its running state; energising then stops the flow and vents. Pick NC when the outlet must be dead until the coil energises. Both states are orderable in the 3V3 family.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac 3V3 Solenoid Valve 3V308NOEIT

Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for 3V308NOEIT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.