verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V3 · 3/2-Way Solenoid Valve

Airtac 3V3 Solenoid Valve 3V308NOET

The AirTAC 3V3 Solenoid Valve 3V308NOET is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/4 in
  • Coil voltageAC24V
  • Electrical entryDIN plug (DIN socket type)
  • Flow (Cv)0.62
  • Series3V3
$70.86 $78.36Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every 3V3-08 voltage, entry and configuration on one page All 3V3-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac 3V3 Solenoid Valve 3V308NOET

The 3V308NOET puts a normally open 3/2 function behind an AC24V coil — the voltage to specify where machines run on low-voltage control circuits and wiring rules favour keeping operator-adjacent solenoids at 24 V. With a 1/4 inch NPT port and DIN plug connection, it feeds air to the outlet whenever the coil is off and vents the line when the 10 VA coil energises.

Inside is a direct-acting, spring-return coaxial poppet that shifts without pilot pressure and seals positively in both 3/2 states. Its Cv of 0.62 is the largest in the 3V range, the valve tolerates -20 to 70 C, and the same body that handles 0-0.8 MPa of compressed air is rated for vacuum down to -102.2 kPa. A manual override is fitted to help with setup and fault-finding.

Airtac 3V3 Solenoid Valve 3V308NOET Technical Specifications

ModelAirtac 3V3 Solenoid Valve 3V308NOET
Series3V3
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Port size1/4 in
ThreadNPT
Coil voltageAC24V
Electrical entryDIN plug (DIN socket type)
Coil power10 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceRated -102.2 kPa to 0.1 MPa
Flow coefficientCv 0.62
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), direct-acting, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V3 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Model Code: Airtac 3V3 Solenoid Valve 3V308NOET

3V3Body — sets the flow, the coil power and whether vacuum is rated.
1/4 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
AC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
NPTPort thread. PT is standard; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V3 Solenoid Valve 3V308NOET Is Used

valve

Water-treatment skid pilot

Pilots a larger diaphragm actuator on a filtration skid wired throughout with AC24V control circuits, keeping the process line open through any control-power interruption.

conveyor_belt

Conveyor stopper cylinder

Holds a spring-return stopper raised across a box conveyor while de-energised, so product flow halts even if the PLC drops out; energising vents the stopper down.

bolt

Fixture swing clamp

Keeps a single-acting swing clamp on a welding fixture engaged through a control failure, releasing the part only when the coil is deliberately energised.

Is the Airtac 3V3 Solenoid Valve 3V308NOET the Right Part?

AirTAC lists the 3V3 as its biggest, highest-flow 3-port body, so only the step-down direction exists. If Cv 0.62 exceeds what the job needs, pick a 3V2 (1/8 or 1/4 port, Cv 0.18-0.19, also rated for vacuum), a 3V2M (Cv 0.1) where a dense multi-station manifold beats raw flow, or a 3V1 for the smallest low-power duties (3.0 W on DC24V). Confirm five points before ordering: port size and thread (NPT on this code), initial state (this code is NO), coil voltage (AC24V here), electrical entry (DIN plug; add an I suffix for flying lead), and whether the circuit sees vacuum. Double-acting cylinders need a 5-port AirTAC 4V valve instead.

Confirm before you order

  • ✓ Port size and thread (PT standard; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V3 Solenoid Valve 3V308NOET FAQ

Cv 0.62 flow coefficient, 0-0.8 MPa operating pressure, vacuum rating -102.2 kPa to 0.1 MPa, -20 to 70 C temperature range, 10 VA on the AC24V coil (DC versions of this family use 6.5 W), IP65 to DIN 40050, NPT1/4 port, 3/2-way normally open.

No. A 3/2 valve has three ports and two states, so it either feeds one line or vents it — right for single-acting (spring-return) cylinders, blow-off, clamps, vacuum switching and pilot duty. A double-acting cylinder needs pressure on both sides, which means a 5-port valve from the AirTAC 4V series.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac 3V3 Solenoid Valve 3V308NOET

Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for 3V308NOET and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.