The AirTAC 3V3 Solenoid Valve 3V308NOET is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V308NOET puts a normally open 3/2 function behind an AC24V coil — the voltage to specify where machines run on low-voltage control circuits and wiring rules favour keeping operator-adjacent solenoids at 24 V. With a 1/4 inch NPT port and DIN plug connection, it feeds air to the outlet whenever the coil is off and vents the line when the 10 VA coil energises.
Inside is a direct-acting, spring-return coaxial poppet that shifts without pilot pressure and seals positively in both 3/2 states. Its Cv of 0.62 is the largest in the 3V range, the valve tolerates -20 to 70 C, and the same body that handles 0-0.8 MPa of compressed air is rated for vacuum down to -102.2 kPa. A manual override is fitted to help with setup and fault-finding.
| Model | Airtac 3V3 Solenoid Valve 3V308NOET |
|---|---|
| Series | 3V3 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Port size | 1/4 in |
| Thread | NPT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 10 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Rated -102.2 kPa to 0.1 MPa |
| Flow coefficient | Cv 0.62 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), direct-acting, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V3 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V3 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| NPT | Port thread. PT is standard; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Pilots a larger diaphragm actuator on a filtration skid wired throughout with AC24V control circuits, keeping the process line open through any control-power interruption.
Holds a spring-return stopper raised across a box conveyor while de-energised, so product flow halts even if the PLC drops out; energising vents the stopper down.
Keeps a single-acting swing clamp on a welding fixture engaged through a control failure, releasing the part only when the coil is deliberately energised.
AirTAC lists the 3V3 as its biggest, highest-flow 3-port body, so only the step-down direction exists. If Cv 0.62 exceeds what the job needs, pick a 3V2 (1/8 or 1/4 port, Cv 0.18-0.19, also rated for vacuum), a 3V2M (Cv 0.1) where a dense multi-station manifold beats raw flow, or a 3V1 for the smallest low-power duties (3.0 W on DC24V). Confirm five points before ordering: port size and thread (NPT on this code), initial state (this code is NO), coil voltage (AC24V here), electrical entry (DIN plug; add an I suffix for flying lead), and whether the circuit sees vacuum. Double-acting cylinders need a 5-port AirTAC 4V valve instead.
Confirm before you order
Cv 0.62 flow coefficient, 0-0.8 MPa operating pressure, vacuum rating -102.2 kPa to 0.1 MPa, -20 to 70 C temperature range, 10 VA on the AC24V coil (DC versions of this family use 6.5 W), IP65 to DIN 40050, NPT1/4 port, 3/2-way normally open.
No. A 3/2 valve has three ports and two states, so it either feeds one line or vents it — right for single-acting (spring-return) cylinders, blow-off, clamps, vacuum switching and pilot duty. A double-acting cylinder needs pressure on both sides, which means a 5-port valve from the AirTAC 4V series.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.