The AirTAC 3V3 Solenoid Valve 3V308NOFT is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
3V308NOFT is the normally open, DC12V version of the AirTAC 3V3 body: a 3/2-way direct-acting poppet valve with spring return that passes air from supply to outlet while de-energised, then vents that line to exhaust when the 6.5 W coil switches on. With Cv 0.62 it is the highest-flow body in the whole 3V range - roughly six times the flow of a base-mounted 3V2M (Cv 0.1) and well clear of 3V208 (Cv 0.19) - so it fits circuits where a smaller 3-port valve would throttle the duty.
The coaxial shut-off construction seals across the full envelope: 0-0.8 MPa in normal service and a vacuum rating of -102.2 kPa to 0.1 MPa for negative-pressure work. Power comes from a DC12V coil drawing 6.5 W, connected through the DIN plug socket on top of the body. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
| Model | Airtac 3V3 Solenoid Valve 3V308NOFT |
|---|---|
| Series | 3V3 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Port size | 1/4 in |
| Thread | NPT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 6.5 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Rated -102.2 kPa to 0.1 MPa |
| Flow coefficient | Cv 0.62 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), direct-acting, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V3 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V3 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/4 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| NPT | Port thread. PT is standard; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A normally open valve is the natural fit for high-volume blow-off: air flows to the air knives whenever control power is off, and energising the 6.5 W DC12V coil cuts the blast between sheets. Cv 0.62 keeps the pressure drop low at the high flows air knives demand.
On a machining centre with big single-acting clamping cylinders, the 3V3 flow headroom refills the clamp volume quickly after each part change. Because the valve is normally open, the clamp stays pressurised if 12 V control power is lost - energise to vent and release.
Bigger vacuum cups on a packaging gantry need both a solid draw and a clean release. The -102.2 kPa to 0.1 MPa rating covers the negative-pressure side, while energising the coil vents the cup line so cartons drop crisply at the pack station.
Step down to 3V2 (1/8in or 1/4in, Cv 0.18-0.19, also vacuum-rated) when Cv 0.62 is more flow than the job needs, to manifold-mounted 3V2M (Cv 0.1) when station density matters more than flow, or to 3V1 (3.0 W on DC24V) for the smallest low-power duties. Match five points before ordering: the NPT1/4 port (G or NPT threads are order options), the normally open initial state, the DC12V coil, the electrical entry - a DIN plug here, with the FI suffix carrying a flying lead instead - and whether the circuit sees vacuum, which 3V3 handles but 3V1 does not. To move a double-acting cylinder you need a 5-port valve: go to the AirTAC 4V series instead.
Confirm before you order
It is a 3/2-way direct-acting poppet valve with spring return: Cv 0.62, operating pressure 0-0.8 MPa, vacuum rating -102.2 kPa to 0.1 MPa, media temperature -20 to 70 C, DC12V coil at 6.5 W, IP65 protection, NPT1/4 ports with a manual override fitted. Air should be filtered to 40 um or finer; lubrication is not required. Effective area, response time, weight and dimensions are not published for this body - confirm any of these from the datasheet via RFQ.
A normally open 3/2 valve passes air from supply to outlet while de-energised and vents the line when the coil is energised - the mirror image of NC. Pick NO where flow is the wanted standby condition: purge and blow-off lines that must keep running through a power cut, cooling jets, or vent circuits. With a 6.5 W DC12V coil the energised state costs little to hold. Like every 3-port valve it feeds or vents a single line, so it drives single-acting cylinders and pilot stages only - a double-acting cylinder needs the 5-port AirTAC 4V series.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.