The AirTAC 4V100 Solenoid Valve 4V120-06-BT is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/8 ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V120-06BT is a 5/2-way double-solenoid directional control valve built on the compact 4V100 aluminum body. It directs compressed air to double-acting cylinders and actuators, using a memory-hold spool design: a brief pulse to either coil shifts the spool, and it stays locked in that last position by land friction and balanced pressure—no holding current, no spring return, and no magnetic latching. This makes it ideal for applications where the valve must retain its state during a power loss or E-stop without complex control logic.
With 1/8" NPT ports and a DC24V 2.8 W terminal-box coil, this 175 g valve delivers an effective area of 10.2 mm² (Cv 0.6) and can cycle up to 5 times per second. Its sub-0.05-second response time ensures crisp, repeatable shifts for small-bore pneumatic systems. The spool-and-sleeve construction operates on filtered, non-lubricated air from 0.15 to 0.8 MPa and is rated IP65 for washdown and dusty environments.
| Model | Airtac 4V100 Solenoid Valve 4V120-06-BT |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 10.2 mm² (Cv 0.6) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 175 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 10.2 mm² |
|---|---|
| Flow coefficient | Cv 0.6 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
A pulse to the 4V120-06BT extends a gripper, and it stays clamped even if the machine enters a pause or E-stop, preventing dropped parts on small benchtop automation cells.
Controls a small pneumatic gate on a conveyor. A momentary signal flips the gate to divert a product, and it holds position without continuous power, saving energy and simplifying wiring.
Drives a double-acting shuttle on a liquid handler. The memory function keeps the shuttle at its destination after a brief PLC pulse, allowing the controller to manage other tasks.
Choose the 4V120-06BT when your double-acting cylinder (typically Ø16-32 mm) needs to hold its last position without a constant electrical signal. The double-solenoid memory function is a perfect fit for clamping, diverting, or indexing stations where the PLC output is a momentary pulse. If your cylinder is larger or you need higher flow, step up to the 4V200 series (Cv 1.0) for faster filling. For a complete replacement, match all five points: 4V100 body size, double-solenoid (20) function, 1/8" port, DC24V coil, and terminal-box entry. Mounting on a manifold base is straightforward and simplifies multi-valve plumbing.
Quick checklist
It means the valve spool stays in its last commanded position after the electrical signal is removed. A momentary pulse to coil A shifts it one way; a pulse to coil B shifts it back. It is held by friction and pressure balance, not by a spring or magnet, so it does not require a holding current.
With a Cv of 0.6 and a 10.2 mm² effective area, it suits double-acting cylinders roughly Ø16-32 mm for typical industrial cycle rates. For larger bores or very high-speed applications, consider the 4V200 series which offers a higher flow capacity.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.