The AirTAC 4V330E-10CI Solenoid Valve, 5/3-way, exhaust center, PT3/8, AC110V, grommet entry (4V330E10CI) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with PT3/8 ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330E-10CI is a 5/3-way double-solenoid pneumatic directional valve that directs compressed air to double-acting cylinders and actuators. Its exhaust center configuration means that when both solenoids are de-energized, the cylinder ports A and B are connected to exhaust, allowing the cylinder to float freely—ideal for applications where the load must be moved manually or come to a gentle, unpowered rest without trapped pressure.
This specific model is configured with an AC110V coil drawing 4.5 VA, a grommet-style electrical entry with a 0.5 m flying lead for quick DIN-connector wiring, and 3/8-inch PT ports. With an effective area of 21.3 mm² (Cv 1.25, catalog figure for the 4V330C-10) and a maximum cycling speed of 3 times per second, it suits ~O50-80 mm bore cylinders in medium-duty automation. The aluminum body weighs 450 g and responds in 0.05 seconds or less.
| Model | AirTAC 4V330E-10CI Solenoid Valve, 5/3-way, exhaust center, PT3/8, AC110V, grommet entry (4V330E10CI) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | PT3/8 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -10 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Controls larger double-acting cylinders on lift-and-transfer stations. The exhaust center lets the cylinder rod float at mid-stroke, preventing trapped pressure when a part is manually aligned or removed.
Operates pneumatic clamps on assembly jigs for O50-80 mm cylinders. At idle, both clamp ports exhaust, so the clamp opens freely without residual force, making part loading and unloading safer.
Directs air to double-acting feed cylinders on drilling or tapping units. The 5/3 exhaust center allows the spindle to be manually retracted during setup, with the AC110V grommet coil simplifying wiring into existing machine panels.
Choose the 4V330E-10CI when your pneumatic circuit needs a 5/3 exhaust-center function on a 3/8-inch ported base. The exhaust center is the right pick when the cylinder rod must be free of holding force at idle—common in manual load positioning or safety-interlocked stations where trapped air is a hazard. If your cylinder is smaller than 50 mm bore, stepping down to a 4V200 series (Cv 1.0) can reduce cost and space; for bores above 80 mm, the 4V400 (Cv 2.82) provides the necessary flow.
For a direct replacement, match five points exactly: the 4V300 body size, the 5/3 exhaust-center function (30E), the 3/8-inch PT port, the AC110V coil voltage, and the grommet (I) electrical entry. This valve can be mounted individually or on a manifold base for multi-valve assemblies.
AirtacDistr lists every 4V330E-10 order code with its price on one page at https://airtacdistr.com/products/airtac-4v330e-10-solenoid-valve
Quick checklist
With a Cv of 1.25 and an effective area of 21.3 mm², it is well-matched to double-acting cylinders in the ~O50-80 mm bore range for typical industrial speeds. For a cylinder at the upper end of that range running at high speed, verify that the valve's 3 cycles-per-second maximum frequency meets your cycle-time requirement.
In the center position (both solenoids off), the 4V330E connects both cylinder ports to the exhaust. This means no pressure is applied to either side of the piston, so the cylinder rod is free to be moved by an external force. It is the correct choice when you need the actuator to 'float' at rest, unlike a closed-center valve which would lock the cylinder in place.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.