The AirTAC 4V320-08CIT Solenoid Valve, 5/2-way, NPT1/4, AC110V, grommet entry (4V32008CIT) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/4 ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V320-08CIT is a 5/2-way double-solenoid pneumatic directional valve built on the 4V300 aluminum body. It directs compressed air to double-acting cylinders and actuators, using a memory-spool design: a momentary pulse to either coil shifts the spool, and it stays locked in that last position even when power is removed—no holding current, no spring. This makes it ideal for clamping, holding, or any sequence where you want the cylinder to remain stationary during a power interruption.
This specific SKU comes with an AC110V coil drawing 4.5 VA and a grommet-style electrical entry with a 0.5 m flying lead for DIN-rail wiring. All ports are 1/4-inch NPT (NPT tapered). The valve body weighs 400 g, delivers an effective area of 28.0 mm² (Cv 1.65), and can cycle at up to 4 times per second. Response time is 0.05 s or less, and the IP65-rated enclosure handles wet, dusty factory conditions without an extra cabinet.
| Model | AirTAC 4V320-08CIT Solenoid Valve, 5/2-way, NPT1/4, AC110V, grommet entry (4V32008CIT) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/4 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 400 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
The memory-spool action holds a pneumatic clamp closed after a brief pulse, so the part stays locked during machining or welding even if the PLC output drops. The 4V320-08CIT’s AC110V grommet lead simplifies wiring inside a crowded control panel.
Pulse the valve to raise a stop gate or swing a diverter on a conveyor line. The double-solenoid design keeps the gate in position without continuous power, reducing coil heat in high-cycle sorting systems.
In a two-hand press control, the 4V320-08CIT extends a cylinder on one pulse and retracts on the next. The 4 c/s max frequency and 0.05 s response keep pace with moderate-speed forming cycles on 63-80 mm bore tooling actuators.
Choose the 4V320-08CIT when your application needs a double-acting cylinder in the ~50-80 mm bore range to hold its last position after a control pulse, even if the machine powers down. The 1/4-inch port size and Cv 1.65 flow capacity sit between the smaller 4V200 (Cv 1.0) and the larger 4V400 (Cv 2.82)—step down to a 4V200 for compact cylinders under 40 mm bore, or up to a 4V400 for 100 mm+ bores that need higher flow. The double-solenoid memory function is the right call over a spring-return 4V310 when you cannot maintain a continuous electrical signal or want to reduce coil heat.
For a direct replacement, match five points exactly: the 4V300 body size, the 5/2 double-solenoid function (20), the 1/4-inch port with NPT thread, the AC110V coil voltage, and the grommet (I) electrical entry. You can also mount this valve on an AirTAC 300-series manifold base to build a compact multi-valve station—just confirm the manifold station matches the grommet wiring layout.
Quick checklist
Because it is a double-solenoid memory valve, the spool simply stays in its last shifted position when power is removed—it does not spring back to a default state. The cylinder will hold its current position (subject to normal internal leakage). This is not a safety-rated load-holding function; for suspended or vertical loads, add a pilot-operated check valve or mechanical brake at the cylinder ports.
No, the 4V320-08CIT is factory-built with an AC110V (4.5 VA) coil and a grommet lead. Using a different voltage will burn the coil or fail to shift the spool. If your system uses DC24V, order the 4V320-08BI instead; for AC220V, choose the 4V320-08AI. Always match the coil voltage code exactly when replacing a valve.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.