Genuine AirTAC three-unit frl, order code AC15001W from the AC-BC range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
AC15001W keeps the compact PT1/8 A-line format of the AF1500C filter, AR1500C regulator and AL1500C lubricator but selects the W-coded 5 um element instead of the 40 um standard, so finer particles are removed before air reaches small valves and actuators.
Regulation is the standard 0.15-0.9 MPa (20-130 psi) range with the fitted GS40 gauge scaled in MPa. The 15 cc bowl drains differentially and manually, the 25 cc lubricator takes ISO VG32 turbine oil, and the set is rated to 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure.
| Order code | AC15001W |
|---|---|
| Product | Three-Unit FRL |
| Model and port | AC1500 · PT1/8 |
| Drain · type | Differential + manual drain · Standard, max 0.9 MPa |
| Gauge · element · thread | Gauge in MPa · 5 µm element (W) · PT thread |
| Models | AC1500, AC2000, BC2000, BC3000, BC4000 |
|---|---|
| Port | AC1500: PT1/8, AC2000: PT1/4, BC2000: PT1/4, BC3000: PT3/8, BC4000: PT1/2 |
| Thread | PT (standard), G, NPT (T) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Drain bowl capacity | A1500/A2000: 15 cc · B2000/B3000: 40 cc · B4000: 60 cc |
| Lubricator capacity | A1500/A2000: 25 cc · B2000/B3000: 60 cc · B4000: 90 cc |
| Components | AF1500C filter + AR1500C regulator + AL1500C lubricator; AF2000C filter + AR2000C regulator + AL2000C lubricator; BF2000C filter + BR2000C regulator + BL2000C lubricator; BF3000C filter + BR3000C regulator + BL3000C lubricator; BF4000C filter + BR4000C regulator + BL4000C lubricator |
| Fluid | Air |
| Regulating range | 0.15 – 0.9 MPa (20 – 130 psi) |
| Low-pressure (L) version | up to 0.4 MPa (58 psi) |
| Maximum pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -5 to +70 °C (no freezing) |
| Recommended oil | ISO VG32 turbine oil |
| Gauge | GS40 on gauge versions |
Source: AirTAC AC/BC series datasheet (p.274, 2025-11 edition, airtac.com), ordering code and specifications.
Take the W code over AC15001 when the 40 um standard element is too coarse for the downstream devices on a PT1/8 line. The remaining choices are unchanged: AC1500N deletes the gauge, AC1500L caps regulation at 0.4 MPa, and AC20001W moves the same 5 um filtration up to a PT1/4 port. The catalog writes the size as 1500C.
AirtacDistr lists every AC-BC order code with its price on one page at https://airtacdistr.com/products/airtac-ac-bc-three-unit-frl
Protect pilot and sensing circuits on PT1/8 feeds where a 40 um element lets particles through; the 5 um W grade cleans air ahead of sensitive orifice and pilot paths.
Run miniature grippers and placement heads on narrow air, combining fine 5 um filtration with the MPa gauge for repeatable low settings in the 0.15-0.9 MPa (20-130 psi) band.
Condition test-rig air at the point of use, where the compact 15 cc / 25 cc set fits on a bench frame and the finer element keeps small-bore test plumbing clean.
PT1/8 ports; AF1500C filter + AR1500C regulator + AL1500C lubricator; 5 um (W) element instead of 40 um; regulating range 0.15-0.9 MPa (20-130 psi); maximum 1.0 MPa (145 psi), proof 1.5 MPa (215 psi); 15 cc drain bowl; 25 cc lubricator; MPa gauge; differential + manual drain.
Only the filtration grade: the 5 um element removes finer particles than the standard 40 um, while pressure range, gauge, bowl and lubricator stay as in AC15001. A finer element loads up sooner, so check it during each drain; replacement intervals are not stated in the summary data, so confirm from the datasheet.