verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart1 Request a QuoteQuote
AirTAC AC-BC · Three-Unit FRL

Airtac AC1500/2000 Triple Unit (F.R.L. Combination Unit) AC20001W

Genuine AirTAC three-unit frl, order code AC20001W from the AC-BC range. The options this code selects are decoded below; series data follow the official AirTAC catalog.

  • Model and portAC2000 · PT1/4
  • Drain · typeDifferential + manual drain · Standard, max 0.9 MPa
  • Gauge · element · threadGauge in MPa · 5 µm element (W) · PT thread
  • ModelsAC1500, AC2000, BC2000, BC3000, BC4000
  • PortAC1500: PT1/8, AC2000: PT1/4, BC2000: PT1/4, BC3000: PT3/8, BC4000: PT1/2
  • ThreadPT (standard), G, NPT (T)
$48.82 $56.32Save 13%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every AC/BC model and port, drain/type and gauge/element/thread on one page All AC/BC codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac AC1500/2000 Triple Unit (F.R.L. Combination Unit) AC20001W

AC20001W is the fine-filtration build of the A-line PT1/4 three-unit set: the AF2000C filter, AR2000C regulator and AL2000C lubricator, with the W option swapping the standard 40 um element for a 5 um element. The digit 1 keeps the MPa gauge, and the pressure side remains the standard 0.15 to 0.9 MPa (20 to 130 psi) regulating range.

Downstream, the tighter 5 um element means the air reaching valves, cylinders and instruments carries far fewer particles, while the differential plus manual drain clears the 15 cc bowl by hand. The lubricator reservoir takes 25 cc of ISO VG32 turbine oil, maximum operating pressure is 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), and the temperature window is -5 to +70 C with no freezing.

Airtac AC1500/2000 Triple Unit (F.R.L. Combination Unit) AC20001W Technical Specifications

Order codeAC20001W
ProductThree-Unit FRL
Model and portAC2000 · PT1/4
Drain · typeDifferential + manual drain · Standard, max 0.9 MPa
Gauge · element · threadGauge in MPa · 5 µm element (W) · PT thread
ModelsAC1500, AC2000, BC2000, BC3000, BC4000
PortAC1500: PT1/8, AC2000: PT1/4, BC2000: PT1/4, BC3000: PT3/8, BC4000: PT1/2
ThreadPT (standard), G, NPT (T)
Filter element40 µm (standard), 5 µm (W)
Drain bowl capacityA1500/A2000: 15 cc · B2000/B3000: 40 cc · B4000: 60 cc
Lubricator capacityA1500/A2000: 25 cc · B2000/B3000: 60 cc · B4000: 90 cc
ComponentsAF1500C filter + AR1500C regulator + AL1500C lubricator; AF2000C filter + AR2000C regulator + AL2000C lubricator; BF2000C filter + BR2000C regulator + BL2000C lubricator; BF3000C filter + BR3000C regulator + BL3000C lubricator; BF4000C filter + BR4000C regulator + BL4000C lubricator
FluidAir
Regulating range0.15 – 0.9 MPa (20 – 130 psi)
Low-pressure (L) versionup to 0.4 MPa (58 psi)
Maximum pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature-5 to +70 °C (no freezing)
Recommended oilISO VG32 turbine oil
GaugeGS40 on gauge versions

Source: AirTAC AC/BC series datasheet (p.274, 2025-11 edition, airtac.com), ordering code and specifications.

How to choose

The decision between AC20001W and its sibling AC20001 is purely the element: W costs you nothing on ports or regulation but filters to 5 um instead of 40 um, so take it whenever solenoid valves, air gauging or measurement devices sit downstream. Everything else matches: PT1/4 ports, MPa gauge, differential plus manual drain, 15 cc and 25 cc reservoirs. If flow demand grows, the equivalent B-line BC2000 in W configuration handles more air and, unlike the A-line, accepts the A automatic-drain option; smaller PT1/8 points use AC1500.

AirtacDistr lists every AC-BC order code with its price on one page at https://airtacdistr.com/products/airtac-ac-bc-three-unit-frl

Applications

sensors

Instrument and air-gauging stations

Measurement circuits are intolerant of fine particles, so the 5 um element protects gauging jets and transducers fed through the PT1/4 line.

valve

Solenoid valve banks

Dense valve islands with narrow internal passages stay cleaner on the W element, and the MPa gauge lets operators verify set pressure at a glance.

precision_manufacturing

Precision assembly stations

Where small pneumatic components seat tightly, filtered-to-5 um supply plus 25 cc of ISO VG32 lubrication reduces wear on close-fit parts.

FAQ

What are the key figures of the AC20001W in one place?

Port PT1/4; filter AF2000C with 5 um element (W), regulator AR2000C, lubricator AL2000C; regulation 0.15 to 0.9 MPa (20 to 130 psi); maximum pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi); differential plus manual drain; 15 cc drain bowl and 25 cc lubricator; MPa gauge; temperature -5 to +70 C (no freezing).

What does the W in AC20001W stand for and when should I skip it?

W selects the 5 um filter element in place of the standard 40 um element. Keep W for sensitive downstream equipment; for general actuator supply where the coarser element is acceptable and marginally less restrictive, order the plain AC20001. Confirm the exact element change-out details from the datasheet.