The AirTAC GAC F.R.L. Unit GAC20006LNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight750 g
$62.38 $69.88Save 10% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GAC200-06 bowl, type and element option on one page All GAC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac GAC F.R.L. Unit GAC20006LNT

Delivering cleaned, regulated and lubricated air for light-duty pneumatics, this AirTAC GAC20006LNT combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/8in port pairs with a 40 um element to protect downstream actuators, while the lower-pressure type restricts the operating band to 0.15-0.4 MPa (20-58 psi). Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the internal pressure-control mechanism.

Weighing 750 g, the assembly carries a 25 cc condensate bowl and a 36 cc oil reservoir, dictating frequent maintenance checks compared to larger frames. This unit omits the pressure gauge entirely; operators must add a 1/8in gauge to the dedicated port to read the setpoint. The standard semi-auto and manual drain pair is fitted, emptying condensate on every pressure drop or on demand. This version has NPT ports (the T in the order code) for North American pipe fittings.

Airtac GAC F.R.L. Unit GAC20006LNT Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC20006LNT
SeriesGAC200 F.R.L. combination
Port size1/8" (NPT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC20006LNT

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
06Port size 1/8". This body offers 06 = 1/8", 08 = 1/4".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
TNPT thread; gauge scale psi / bar.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/8" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC20006LNT Is Used

precision_manufacturing

Micro-Pneumatic Clamps

Feeds clean, lubricated air at low pressure to delicate clamping cylinders on electronics assembly lines.

science

Laboratory Air Tools

Conditions supply for benchtop air agitation or small laboratory pick-and-place arms requiring 40 um filtration.

handyman

Single-Actuator Jigs

Prepares air for individual pneumatic presses in low-force welding jigs, utilizing the 36 cc oil bowl for steady misting.

Is the Airtac GAC F.R.L. Unit GAC20006LNT the Right Air-Prep Unit?

Choose this 1/8in body for single actuators or small jigs where the catalogue flow curve is plotted to 1750 L/min at 0.7 MPa inlet, which is roughly 29% of the GAC300's 3000 L/min envelope. The PC bowl suits standard -5 to 70 C environments, but buyers facing aggressive solvents should confirm material compatibility from the datasheet. If the machine requires oil-free exhaust, omit the lubricator and select a standalone filter-regulator instead. The three components are individually replaceable using GAF200-06, GAR200-06 and GAL200-06 spares. Remember that the 0.4 MPa ceiling is 44% of the standard 0.9 MPa limit, so never specify this lower-pressure variant if the equipment might later need higher force.

Quick checklist

  • ✓ Body size for your peak flow (1/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC20006LNT FAQ

This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 750 g, holds 25 cc of condensate and 36 cc of oil, and requires ISO VG 32 lubricant.

The N in the ordering code means no gauge is supplied. The block retains a 1/8in gauge connection, so you must install a separate gauge reading in MPa/psi to verify the downstream set pressure.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC20006LNT

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GAC20006LNT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.