verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAC200 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC200N06ALTK

The AirTAC GAC F.R.L. Unit GAC200N06ALTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeCircular, psi / bar
  • Weight750 g
$94.00 $101.50Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GAC200-06 bowl, type and element option on one page All GAC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac GAC F.R.L. Unit GAC200N06ALTK

Delivering cleaned, regulated and lubricated air for compact pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 1/8in port serves low-pressure duties, governing output between 0.15-0.4 MPa (20-58 psi) through a 40 um element. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the pressure-control mechanism.

Built with a nylon bowl and weighing 750 g, the assembly incorporates an automatic drain that expels condensate from the 25 cc bowl without operator input. A circular gauge reading MPa/psi is fitted for the default NPT thread, and the assembly includes a reverse-flow (reflux) valve, shown as a separate pneumatic symbol in the catalogue. If the downstream line must remain oil-free, omit the lubricator and choose a dedicated filter-regulator instead. Order code GAC200N06ALTK has NPT ports (the T in the code) for North American pipe fittings.

Airtac GAC F.R.L. Unit GAC200N06ALTK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC200N06ALTK
SeriesGAC200 F.R.L. combination
Port size1/8" (NPT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.

Model Code: Airtac GAC F.R.L. Unit GAC200N06ALTK

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
06Port size 1/8". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
TNPT thread; gauge scale psi / bar.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/8" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC200N06ALTK Is Used

precision_manufacturing

Small Pneumatic Jigs

Conditions air for delicate pick-and-place jigs operating at low pressure, ensuring smooth actuator cycling without over-pressurizing fragile components.

science

Lab Automation

Supplies a steady, lubricated air supply to benchtop analytical instruments where a compact 1/8in port and precise 0.15-0.4 MPa control are required.

handyman

Miniature Air Tools

Prepares air for low-torque miniature air screwdrivers and grinders, adding necessary oil mist downstream to protect internal vanes from wear.

Is the Airtac GAC F.R.L. Unit GAC200N06ALTK the Right Air-Prep Unit?

This 1/8in body targets single actuators or small jigs where space and flow are constrained; stepping up to the GAC300 increases the plotted flow envelope from 1750 L/min to 3000 L/min at 0.7 MPa inlet. The nylon bowl suits standard -5 to 70 C environments, while the automatic drain minimises manual intervention for the 25 cc condensate capacity. Replacement spares follow the body-port suffix directly: GAF200-06, GAR200-06 and GAL200-06. Choosing the lower-pressure type means the 0.4 MPa ceiling is just 44% of the 0.9 MPa standard maximum, so select this only if the machine will never require higher pressure.

Quick checklist

  • ✓ Body size for your peak flow (1/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC200N06ALTK FAQ

This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, the filtering grade is 40 um, and it uses ISO VG 32 lubricant. It features a 25 cc drain bowl, a 36 cc oil bowl, and weighs 750 g.

The K indicates that a reverse-flow (reflux) valve is fitted to this assembly. The catalogue depicts this as a distinct pneumatic symbol with further details available on its dedicated page; no functional description is provided in the standard data.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC200N06ALTK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GAC200N06ALTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.