The AirTAC GAC F.R.L. Unit GAC200N06LT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for single actuators, this AirTAC unit integrates a filter, regulator and lubricator on one L-shape bracket with quick clamps. The 1/8in port serves small pneumatic jigs, and the lower pressure type governs output from 0.15-0.4 MPa (20-58 psi) using a 40 um element.
Air passes through the filter first, then the regulator, before oil mist is added last by the lubricator so the regulator seat stays clean. The nylon bowl holds 25 cc of condensate and 36 cc of oil, while the fitted circular gauge reads MPa/psi for the default NPT thread. Order code GAC200N06LT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC200N06LT |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds filtered and oiled air at low pressure to delicate testing jigs requiring precise actuation without high force.
Conditions air for single-station handheld drivers where a 1/8in port and a compact 750 g footprint fit tight benches.
Regulates low-pressure cylinders in laboratory equipment, keeping the 0.15-0.4 MPa range stable for sensitive movements.
Choose this 750 g assembly for tight spaces where tubing cannot support the load, requiring a proper panel mount. The nylon bowl suits standard -5 to 70 C environments, and the semi-auto plus manual drain pair dumps condensate on every pressure drop or on demand. If the machine needs oil-free output downstream, omit the lubricator and choose a separate filter-regulator. Replacement parts share the 200-06 suffix: GAF200-06, GAR200-06 and GAL200-06. Stepping up to the GAC300 body increases the plotted flow envelope to 3000 L/min at 0.7 MPa inlet from this body's 1750 L/min, but choosing this L type means the 0.4 MPa ceiling is 44% of the standard 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower pressure unit operates at 0.15-0.4 MPa (20-58 psi) with a 1.0 MPa (145 psi) max pressure and a 1.5 MPa (215 psi) proof pressure. It handles -5 to 70 C temperatures, uses a 40 um element, weighs 750 g, has a 25 cc drain bowl, a 36 cc oil bowl, and recommends ISO VG 32 lubricant.
The N before the port indicates a nylon bowl, and the L signifies the lower pressure type with a 0.15-0.4 MPa range. A circular gauge reading MPa/psi is fitted as standard.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.