The AirTAC GAC F.R.L. Unit GAC200N06SNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for single actuators, this AirTAC GAC200N06SNT F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/8in port and 750 g weight make it a compact choice for tight panels, while the standard type regulates pressure from 0.15-0.9 MPa (20-130 psi). It uses a 40 um element and a nylon bowl to condition supply air.
Because the code carries an N after the port, no pressure gauge is supplied from the factory; the body has a 1/8in gauge connection if you need to add one later to read the setpoint. The build order is strictly filter, then regulator, then lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Condensate is managed by a semi-auto and manual drain pair, discharging 25 cc of water on each pressure drop or on demand. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC200N06SNT |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds single-acting cylinders on benchtop assembly jigs where a 1/8in port and 750 g mass fit neatly into confined control boxes.
Provides the required oil mist for small air motors in handheld manufacturing tools, extending mechanism life without flooding the line.
Conditions air for low-flow actuator setups in laboratory environments, delivering stable 0.15-0.9 MPa pressure for delicate valve operations.
This 1/8in unit suits light-duty jigs where space is tight. If your machine header demands a higher flow envelope, stepping up to the GAC300 body shifts the plotted curve from 1750 L/min to 3000 L/min at 0.7 MPa inlet. Here, the 40 um element handles general shop air, whereas a 5 um W variant would trap finer grit for precision pneumatics. Should your downstream process require strictly oil-free air, omit the lubricator and choose a dedicated filter-regulator instead. For maintenance, this assembly uses GAF200-06, GAR200-06 and GAL200-06 spares. Keep in mind that max supply is 1.0 MPa and the standard type regulates to 0.9 MPa, leaving only about 0.1 MPa of headroom above the top setting.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
The standard type operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It functions from -5 to 70 C, weighs 750 g, holds 25 cc of condensate and 36 cc of oil, and uses ISO VG 32 lubricant.
The N after the port code indicates no gauge is supplied. The body features a 1/8in gauge connection, allowing you to install your own pressure indicator to monitor the 0.15-0.9 MPa range if visual confirmation of the setpoint is needed.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.