The AirTAC GAC F.R.L. Unit GAC200N06SNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GAC200N06SNWT is a compact three-unit F.R.L. combination - filter, regulator and lubricator - pre-assembled on a single L-shape bracket with quick mounting clamps. The 1/8in port and 750 g mass place it at the entry of the GAC size range, suited to feeding a single small actuator or a bench jig rather than a whole machine header. Air passes through the 5 um filter element first, then the regulator holds 0.15-0.9 MPa (20-130 psi), and the lubricator adds oil mist last, downstream of the regulator seat so the oil never fouls the pressure control.
The nylon bowl is a build choice for this unit, and the common specification applies exactly as for the PC or metal versions: max pressure 1.0 MPa (145 psi), proof 1.5 MPa (215 psi), and a -5 to 70 C operating range that must not freeze. No gauge is supplied with this model, so the set pressure cannot be read without adding one; the gauge connection is 1/8in if you fit one later. The 25 cc condensate bowl and 36 cc oil bowl set the service rhythm for this small body class. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC200N06SNWT |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Powers one pneumatic cylinder on a small assembly fixture, where the 5 um element protects a precision valve from fine particulates.
Conditions air for a manual press or clamping jig in a repair shop, with the semi-auto drain clearing condensate on each pressure drop.
Supplies a small laboratory pneumatic actuator that needs clean, regulated air at a stable pressure within the 0.15-0.9 MPa range.
Choose the GAC200 body when the downstream demand is modest - its 1/8in port and 25 cc drain bowl suit a single cylinder or a small fixture. The nylon bowl (N) is the material option here, and the 5 um element (W) traps finer particles than the standard 40 um grade, which suits precision valves but means more frequent element service. This model ships with both semi-auto and manual drains: the semi-auto dumps condensate each time supply pressure drops, and the manual drain gives on-demand control. The standard type (S) regulates 0.15-0.9 MPa (20-130 psi), and since no gauge (N) is fitted, plan to add one at the 1/8in connection if operators need to read the setpoint. The NPT thread carries an MPa/psi gauge scale when a gauge is added. Spare units for this body-port are GAF200-06, GAR200-06 and GAL200-06. The regulation headroom above the top setting is only about 0.1 MPa, since the max supply is 1.0 MPa and the regulator tops out at 0.9 MPa - so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
It operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. The drain bowl holds 25 cc and the oil bowl holds 36 cc, with a total weight of 750 g.
The N after the port code means no gauge is supplied with this unit, so you cannot read the set pressure directly. If you need to monitor the outlet pressure, you can add a gauge at the 1/8in gauge connection on the regulator body.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.