The AirTAC GAC F.R.L. Unit GAC30015ALNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in ported body hosts a 5 um element for fine particle capture, while the automatic drain clears condensate without operator intervention. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the pressure-control mechanism.
Configured for low-pressure duties, the unit regulates between 0.15-0.4 MPa (20-58 psi) and carries no gauge, leaving a 1/8in connection for adding instrumentation as needed. The 60 cc condensate sump and 98 cc oil reservoir dictate the maintenance rhythm, and the 1300 g mass requires a firm panel mount rather than tubing support. If the application must remain oil-free, omit the lubricator and choose a dedicated filter-regulator instead. Order code GAC30015ALNWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30015ALNWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds instrument air to sensitive solenoid banks where the 5 um element protects tight clearances from particulate damage.
Supplies regulated, lubricated air to packaging equipment operating under 0.4 MPa to prevent crushing delicate cartons.
Conditions air for test fixtures requiring stable, low-pressure actuation and continuous unattended drainage via the auto drain.
Choose this configuration for low-pressure circuits requiring fine filtration, noting that the 0.15-0.4 MPa (20-58 psi) operating ceiling makes it unsuitable for systems that might later demand higher actuation force. The 5 um element traps finer particulates than the standard 40 um grade, protecting precision valves at the cost of more frequent replacement. The automatic drain suits unattended or wet lines, and the missing gauge means the set pressure cannot be read unless one is added to the 1/8in port. Spares follow the GAF300-15, GAR300-15 and GAL300-15 part numbers. Stepping up to the GAC400 body increases the plotted flow envelope from 3000 to 6000 L/min at 0.7 MPa inlet, doubling the capacity, while the 0.4 MPa ceiling is 44% of the standard 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It features a 60 cc drain bowl, a 98 cc oil bowl, and weighs 1300 g.
The N in the product code signifies that no circular gauge is supplied, meaning the set pressure cannot be visually read without adding one. The body features a 1/8in gauge connection, allowing operators to install a compatible NPT-threaded gauge reading in MPa/psi if visual monitoring is required.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.