The AirTAC GAC F.R.L. Unit GAC30015ALWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for low-pressure pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port serves the GAC300 body, which pairs a 60 cc condensate bowl with a 98 cc oil reservoir. Because the 5 um element sits upstream of the regulation stage, fine particulate is trapped before it can reach the seat, while oil mist is injected last to protect downstream cylinders without fouling the regulator.
This configuration uses a PC bowl and an automatic drain, clearing water without an operator during each cycle. The lower-pressure type restricts output to 0.15-0.4 MPa (20-58 psi), making it unsuitable for any machine that might later need standard 0.9 MPa air. A circular gauge is fitted, reading MPa/psi for the default NPT thread, so technicians can verify the setpoint directly at the unit. Order code GAC30015ALWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30015ALWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive pneumatic grippers and small-bore cylinders on electronics assembly lines where operating pressure must stay below 0.4 MPa to prevent component damage.
Conditions air for flow wrappers and pouch sealers, using the 5 um element to protect delicate timing valves from particulate ingress while the auto drain handles condensate.
Regulates low-pressure air for test fixtures and sample handling, benefiting from the 1/2in port and pre-plumbed bracket to minimize internal leak paths.
Choose this assembly for 1/2in lines that require precise low-pressure control and fine 5 um filtration. The automatic drain is decisive for wet systems or unattended machinery, whereas the standard blank drain option ships with both semi-auto and manual mechanisms for attended stations. If the application requires completely oil-free downstream air, the lubricator here must be omitted and a separate filter-regulator chosen instead. Should a component fail, you can order spares individually using the GAF300-15, GAR300-15 and GAL300-15 designations.
For sizing context, the catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, which is exactly double the 1750 L/min envelope of the smaller GAC200. Keep in mind that the 0.4 MPa ceiling of this L type is 44% of the 0.9 MPa standard limit, so verify your actuators will never need more pressure.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, the filtering grade is 5 um, and the unit weighs 1300 g. It features a 60 cc drain bowl, a 98 cc oil bowl, and requires ISO VG 32 or equivalent lubricant.
The W code specifies a 5 um element, which traps far finer particles than the standard 40 um filter, making it ideal for precision valves or instrument air, though it will require more frequent element service. The A code indicates an automatic drain is fitted, which clears condensate from the 60 cc bowl without an operator, a crucial feature for unattended or high-moisture lines.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.