verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAC300 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC30015ASNTK

The AirTAC GAC F.R.L. Unit GAC30015ASNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialPC
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight1300 g
$98.36 $105.86Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GAC300-15 bowl, type and element option on one page All GAC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac GAC F.R.L. Unit GAC30015ASNTK

Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this GAC30015ASNTK combination integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/2in port serves the 1300 g body, while the internal flow path passes through the filter first, then the regulator, and finally the lubricator so oil mist is added downstream of the regulator seat.

This specific unit carries a 40 um element, a PC bowl, and an automatic drain that clears the 60 cc condensate bowl without an operator. Because the code contains an N after the port, no gauge is supplied; the 1/8in gauge connection allows adding one if reading the set pressure becomes necessary. The standard type regulates from 0.15-0.9 MPa (20-130 psi) and the assembly includes a reverse-flow valve, which the catalogue shows as a separate pneumatic symbol with details on its own page.

Selection should weigh the 1/2in port against the neighbouring GAC400, which steps up to a 100 cc drain bowl and a flow envelope plotted to 6000 L/min at 0.7 MPa inlet compared to this body's 3000 L/min curve. This model uses the automatic drain for unattended lines, whereas a blank drain code ships both semi-auto and manual options. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. The three units are separately orderable as GAF300-15, GAR300-15 and GAL300-15, meaning a clogged element does not require replacing the whole assembly. Stepping from this 3000 L/min envelope to the GAC200's 1750 L/min curve yields a 1.7x flow difference, providing a clear sizing step down for lighter duties. This version has NPT ports (the T in the order code) for North American pipe fittings.

Airtac GAC F.R.L. Unit GAC30015ASNTK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC30015ASNTK
SeriesGAC300 F.R.L. combination
Port size1/2" (NPT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialPC
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1300 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC30015ASNTK

GAC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
TNPT thread; gauge scale psi / bar.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC300 · 1/2" · curve to 3000 L/min
One size downGAC200
One size upGAC400 (curve to 6000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC30015ASNTK Is Used

package_2

Packaging Machine Air Prep

Feeds a 1/2in pneumatic header on a form-fill-seal line, supplying steady 0.15-0.9 MPa pressure to bagging cylinders while the automatic drain handles condensate during continuous shifts.

conveyor_belt

Conveyor Divertor Station

Conditions air for a multi-valve sorting divertor, using the 40 um element to protect spools and the lubricator to oil the moving divertor actuators.

factory

Automated Assembly Cell

Prepares supply for a localized assembly cell, adding oil mist downstream of the regulator to maintain speed on pick-and-place grippers without fouling the regulator seat.

Is the Airtac GAC F.R.L. Unit GAC30015ASNTK the Right Air-Prep Unit?

Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this GAC30015ASNTK combination integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/2in port serves the 1300 g body, while the internal flow path passes through the filter first, then the regulator, and finally the lubricator so oil mist is added downstream of the regulator seat.

This specific unit carries a 40 um element, a PC bowl, and an automatic drain that clears the 60 cc condensate bowl without an operator. Because the code contains an N after the port, no gauge is supplied; the 1/8in gauge connection allows adding one if reading the set pressure becomes necessary. The standard type regulates from 0.15-0.9 MPa (20-130 psi) and the assembly includes a reverse-flow valve, which the catalogue shows as a separate pneumatic symbol with details on its own page.

Selection should weigh the 1/2in port against the neighbouring GAC400, which steps up to a 100 cc drain bowl and a flow envelope plotted to 6000 L/min at 0.7 MPa inlet compared to this body's 3000 L/min curve. This model uses the automatic drain for unattended lines, whereas a blank drain code ships both semi-auto and manual options. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. The three units are separately orderable as GAF300-15, GAR300-15 and GAL300-15, meaning a clogged element does not require replacing the whole assembly. Stepping from this 3000 L/min envelope to the GAC200's 1750 L/min curve yields a 1.7x flow difference, providing a clear sizing step down for lighter duties.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1300 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC30015ASNTK FAQ

This unit operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, the filtering grade is 40 um, and the recommended lubricant is ISO VG 32. It features a 60 cc drain bowl, a 98 cc oil bowl, and weighs 1300 g.

The N after the port in the model code indicates that no gauge is supplied from the factory. The body has a 1/8in gauge connection, allowing operators to add a compatible gauge if they need to visually monitor the 0.15-0.9 MPa set pressure.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC30015ASNTK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GAC30015ASNTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.