The AirTAC GAC F.R.L. Unit GAC30015ASNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatic setups, this GAC30015ASNWTK assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port serves machines needing a standard 0.15-0.9 MPa (20-130 psi) operating range, while the 5 um element captures fine particulates before they reach sensitive valves. An automatic drain empties the 60 cc condensate bowl without operator intervention, and a reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue.
Air travels through the filter first, then the regulator, with oil mist injected last so the regulating seat stays clean. Because the N in the code follows the port, no pressure gauge is supplied; the 1/8in gauge connection allows a separate instrument to be added later. The 98 cc oil bowl sets the lubrication refill interval, and the 1300 g mass requires a firm panel mount rather than tubing support. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30015ASNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds 1/2in actuated gates and sorters on a high-speed packaging conveyor, where the 5 um element protects directional valves from fine grit.
Conditions air for multi-station textile looms, relying on the automatic drain to clear condensate continuously during humid production runs.
Supplies regulated, lubricated air to test fixtures and clamping cylinders, benefiting from the reverse-flow valve fitted to this specific assembly.
Choose this configuration when a 1/2in line requires fine 5 um filtration and unattended condensate removal via the automatic drain. The PC bowl suits standard -5 to 70 C environments, but compatibility should be confirmed for aggressive surroundings. If the application must remain oil-free, omit the lubricator and select a filter-regulator instead. For maintenance, the individual elements are separately orderable as GAF300-15, GAR300-15 and GAL300-15.
Sizing against a larger neighbour, the GAC300 flow curve is plotted to 3000 L/min at 0.7 MPa inlet, which is 50% of the GAC400's 6000 L/min envelope. Regarding supply pressure, the 1.0 MPa maximum inlet leaves only about 0.1 MPa of headroom above the 0.9 MPa standard setting, so plan a supply near 1.0 MPa if you truly need maximum output.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C, uses a 60 cc drain bowl and a 98 cc oil bowl, weighs 1300 g, and requires ISO VG 32 or equivalent lubricant.
The N positioned after the 1/2in port code indicates no gauge is supplied. The body features a 1/8in gauge connection, allowing operators to install a separate NPT-threaded gauge reading in MPa/psi to monitor the 0.15-0.9 MPa set pressure.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.