The AirTAC GAC F.R.L. Unit GAC300C15ALNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in ported body is fitted with a metal bowl and a 5 um element, operating within the lower pressure range of 0.15-0.4 MPa (20-58 psi).
Air passes through the filter first, then the regulator, before oil mist is added downstream by the lubricator so the regulator seat never gets fouled. An automatic drain clears the 60 cc condensate bowl without operator intervention, and because no gauge is supplied, the set pressure must be verified externally via the 1/8in gauge connection. Order code GAC300C15ALNWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C15ALNWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate pneumatic clamps on electronics assembly lines where actuator force must stay below 0.4 MPa to avoid crushing components.
Conditions air for packaging machinery heat-seal jaws, ensuring the 5 um element prevents fine particulates from clogging precision flow controls.
Supplies stable, low-pressure air to sensitive lab automation actuators, with the metal bowl providing durability in demanding environments.
Choose this configuration for unattended lines requiring fine 5 um filtration and low-pressure control up to 0.4 MPa, where the metal bowl suits harsher environments. If the machine might ever need standard pressure, the L type is the wrong part since it tops out at 0.4 MPa. Because oil mist is added downstream, choose a filter-regulator instead if the line must stay oil-free. Replacement spares share the same body-port suffix: GAF300-15, GAR300-15 and GAL300-15. Note that 0.4 MPa is 44% of the Standard type's 0.9 MPa ceiling, so verify your actuators can operate on this restricted supply before ordering.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type unit regulates from 0.15-0.4 MPa (20-58 psi) and has a max pressure of 1.0 MPa (145 psi) with a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, features a 60 cc drain bowl and a 98 cc oil bowl, and uses ISO VG 32 lubricant.
The N in the ordering code indicates no gauge is supplied. To read the set pressure, an operator must add a separate gauge to the 1/8in gauge connection on the body, ensuring the scale matches the NPT thread of MPa/psi.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.