The AirTAC GAC F.R.L. Unit GAC300C15ALNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC GAC300C15ALNWTK combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a 5 um element to trap fine particles before they reach precision valves, while the lower pressure type restricts the operating band to 0.15-0.4 MPa (20-58 psi). Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the internal pressure-control mechanisms.
Built with a durable metal bowl, this 1300 g assembly relies on an automatic drain to purge condensate from the 60 cc sump without operator intervention. No pressure gauge is supplied, but the body features a 1/8in gauge connection if visual monitoring is added later. This specific configuration also carries a reverse-flow (reflux) valve, which the catalogue illustrates as a separate pneumatic symbol with details on its own page, alongside a NPT thread that pairs with an MPa/psi gauge scale.
| Model | Airtac GAC F.R.L. Unit GAC300C15ALNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds instrument-quality air to sensitive solenoid valve banks, where the 5 um element prevents sticking and the low 0.4 MPa ceiling protects delicate diaphragms.
Conditions air for packaging lines that use soft-grip pneumatic clamps, ensuring consistent actuation without over-pressurizing delicate product contact points.
Prepares supply air for benchtop test fixtures, using the metal bowl and automatic drain to handle continuous operation in wet, unattended environments.
Choosing this 1/2in GAC300 means sizing against its neighbours: its catalogue flow curve is plotted to 3000 L/min at 0.7 MPa inlet, sitting neatly between the 1750 L/min envelope of the smaller GAC200 and the 6000 L/min capacity of the larger GAC400. The 5 um element provides finer filtration than the standard 40 um grade, demanding more frequent element swaps to protect sensitive instrumentation. If the downstream line must remain completely oil-free, this lubricator must be omitted entirely in favour of a standalone filter-regulator. Maintenance is straightforward since the individual components are separately orderable as GAF300-15, GAR300-15 and GAL300-15.
Keep in mind that the lower pressure type caps the ceiling at 0.4 MPa, which is 44% of the 0.9 MPa maximum offered by the standard type, so verify your actuators do not require higher force before specifying this unit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This unit operates within a 0.15-0.4 MPa (20-58 psi) pressure range, with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The operating temperature spans -5 to 70 C, utilizing a 5 um filter element. The metal bowl assembly weighs 1300 g, featuring a 60 cc drain bowl capacity and a 98 cc oil bowl capacity. ISO VG 32 is the recommended lubricant for the lubricator section.
No gauge is supplied with this configuration, but a 1/8in connection is available on the body to mount one if visual pressure verification is needed. Additionally, this model includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol with specific functional details listed on its own dedicated page.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.