The AirTAC GAC F.R.L. Unit GAC300C15ASNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic machinery, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in ported body operates at 0.15-0.9 MPa (20-130 psi) and uses a 40 um element to protect downstream components from particulate fouling.
Because no pressure gauge is supplied, the 1/8in gauge connection allows operators to add instrumentation as needed. The metal bowl equips this assembly for harsher industrial settings, while the automatic drain clears condensate without manual intervention. A reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page. Order code GAC300C15ASNTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C15ASNTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds multiple pneumatic wrenches and actuators on a vehicle production track, using the automatic drain to handle high condensate volumes during continuous shifts.
Supplies steady 0.15-0.9 MPa pressure to folding and gluing cylinders, ensuring consistent flap closure on high-speed packaging conveyors.
Conditions air for sensitive test fixtures where the metal bowl offers solvent resistance, while the 40 um element protects precision valves from grit.
Choose this 1300 g assembly when a mid-size body is required with a 1/2in port and durable metal bowl. The automatic drain clears the 60 cc condensate sump independently, reducing maintenance visits compared to a manual setup. If your machine line must remain oil-free, omit the lubricator and select a dedicated filter-regulator instead, as this unit adds oil mist downstream of the regulator. The constituent parts are individually replaceable using GAF300-15, GAR300-15 and GAL300-15 spares. Stepping down to a GAC200 reduces the plotted flow envelope from 3000 L/min to 1750 L/min at 0.7 MPa inlet, roughly a 58% drop. Keep in mind that the 1.5 MPa (215 psi) proof pressure against the 1.0 MPa (145 psi) maximum provides a 1.5x burst-test margin, not permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, and uses a 60 cc drain bowl alongside a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
No, the N in the ordering code means no gauge is supplied. You can add a circular gauge to the 1/8in connection port; for the default NPT thread, the gauge scale will read in MPa/psi.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.