The AirTAC GAC F.R.L. Unit GAC300C15ASWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatic setups, this GAC300C15ASWT combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a 5 um element to trap fine particles before they reach sensitive valves. A metal bowl houses the 60 cc condensate sump, while the 98 cc oil reservoir feeds downstream moving parts. Standard type regulation operates from 0.15-0.9 MPa (20-130 psi).
The automatic drain clears accumulated water without an operator, suiting unattended machinery. Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat stays clean. A circular gauge is fitted, reading MPa/psi for the default NPT thread. The three units are separately orderable as GAF300-15, GAR300-15 and GAL300-15, meaning a clogged element does not require replacing the whole assembly.
| Model | Airtac GAC F.R.L. Unit GAC300C15ASWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds multi-actuator weaving looms where fine 5 um filtration protects intricate air-jet nozzles from clogging.
Conditions air for high-speed capping heads, utilizing the automatic drain to handle moisture in wet washdown zones.
Supplies regulated, lubricated air to pneumatic tool change arms, ensuring smooth actuation and preventing stiction.
Choose this metal bowl configuration for harsher environments where polycarbonate might risk impact damage. The 5 um W element catches far finer particulates than the standard 40 um grade, trading off slightly more frequent element service for better protection of precision instruments. If your machine may need oil-free exhaust downstream, omit the lubricator and choose a filter-regulator instead. The GAC300 catalogue flow curve is plotted to 3000 L/min at 0.7 MPa inlet, whereas the GAC400 reaches 6000 L/min, so size up if your duty point exceeds this envelope. Stepping up to a GAC400 also doubles the condensate capacity to 100 cc, halving intervention frequency. With a 1.0 MPa maximum supply and a 0.9 MPa top setting, there is only about 0.1 MPa of regulation headroom, so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, and features a 60 cc drain bowl alongside a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
The W code specifies a 5 um element, trapping much finer particles than the standard 40 um filter for sensitive instrumentation. The A code denotes the automatic drain, which expels condensate on every pressure cycle without manual intervention, making it ideal for unattended equipment.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.