verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAC300 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC300C15LNT

The AirTAC GAC F.R.L. Unit GAC300C15LNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1300 g
$87.46 $94.96Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GAC300-15 bowl, type and element option on one page All GAC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac GAC F.R.L. Unit GAC300C15LNT

Delivering cleaned, regulated and lubricated air for pneumatic setups, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The GAC300C15LNT features a 1/2in port and uses a 40 um element to strip moisture and solid particles before the regulator sets a stable downstream pressure. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the internal mechanism.

Configured for low-pressure duties, this standard element variant operates from 0.15-0.4 MPa (20-58 psi). It carries a metal bowl and omits the pressure gauge, leaving a 1/8in gauge connection for operators to add their own indicator if required. The 1300 g assembly includes a 60 cc condensate bowl and a 98 cc oil reservoir, both of which dictate how frequently a technician must attend to the unit during routine maintenance rounds. This version has NPT ports (the T in the order code) for North American pipe fittings.

Airtac GAC F.R.L. Unit GAC300C15LNT Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC300C15LNT
SeriesGAC300 F.R.L. combination
Port size1/2" (NPT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1300 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC300C15LNT

GAC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
TNPT thread; gauge scale psi / bar.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC300 · 1/2" · curve to 3000 L/min
One size downGAC200
One size upGAC400 (curve to 6000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC300C15LNT Is Used

precision_manufacturing

Low-Force Clamping Fixtures

Feeds delicate pneumatic clamps on machining centers where output must stay below 0.4 MPa to avoid crushing thin-walled aluminum components.

package_2

Light-Duty Packaging Lines

Conditions air for small pick-and-place actuators in cardboard boxing machines, adding the required oil mist for high-speed moving seals.

science

Laboratory Pneumatic Boards

Prepares supply air for sensitive lab test benches, utilizing the metal bowl for durability against accidental impacts in shared workspaces.

Is the Airtac GAC F.R.L. Unit GAC300C15LNT the Right Air-Prep Unit?

Choose this specific configuration when a machine requires a maximum operating ceiling of 0.4 MPa, as the lower-pressure type limits output to prevent over-pressurization of sensitive downstream components. If the equipment might ever demand more than 0.4 MPa, the L type is the wrong part and a standard S type should be selected instead. The metal bowl offers a robust housing choice for demanding industrial environments, while the semi-auto and manual drain pairing gives operators two distinct methods for clearing the 60 cc condensate sump. Since no gauge is supplied, the set pressure cannot be read without adding one to the 1/8in connection.

For maintenance, the assembly accepts its own AirTAC GAF300-15, GAR300-15 and GAL300-15 replacement units, meaning a clogged element or damaged bowl does not require replacing the whole combination. If the downstream line must remain completely oil-free, the lubricator must be omitted entirely and a standalone filter-regulator chosen instead. Stepping up from this body, the GAC400 plots a flow envelope to 6000 L/min at 0.7 MPa inlet, exactly double the 3000 L/min envelope of the GAC300. However, selecting the L type means the 0.4 MPa ceiling is just 44% of the 0.9 MPa maximum offered by the standard S type.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1300 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC300C15LNT FAQ

This lower-pressure unit regulates air from 0.15-0.4 MPa (20-58 psi) and has a maximum pressure of 1.0 MPa (145 psi) with a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -5 to 70 C, uses a 40 um element, holds 60 cc of condensate and 98 cc of oil, weighs 1300 g, and requires ISO VG 32 lubricant.

The N in the model code indicates no gauge is supplied, leaving a 1/8in gauge connection open on the body. Operators must install their own gauge to read the set pressure, allowing facilities to standardize on a specific dial scale or digital reader that matches their existing equipment.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC300C15LNT

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GAC300C15LNT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.